Campbell Hausfeld CS Serie Manual De Uso página 10

Ocultar thumbs Ver también para CS Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions
Wiring Diagram (Continued)
TO SUPPLY
L1
L2
L3
CT
OFF ON
COL
ESTOP
BRANCH CIRCUIT PROTECTION AND DISCONNECT TO BE PROVIDED BY QUALIFIED INSTALLER. INSTALL IN
ACCORDANCE WITH ALL LOCAL, STATE, AND NATIONAL CODES.
FIELD WIRING TERMINALS SHALL USE MIN 90 DEG C COPPER CONDUCTORS ONLY. TORQUE FIELD WIRING
TERMINAL SCREWS TO 25 IN LBS.
10
www.campbellhausfeld.com
L1
L2
L3
LEGEND
CT
CONTROL TRANSFORMER
COL
COIL OVERLOAD
FOL
FAN OVERLOAD
HATR
HIGH AIR TEMPERATURE RELAY
HPR
HIGH PRESSURE RELAY
TR
TIMER RELAY
TPS
SWITCH, TANK PRESSURE
M
CONTACTOR-MAIN
HPS
SWITCH, HIGH PRESSURE
FOL
HATR 1
HPR 1
RESET
HATR 2
9
5
HPR 2
HATR 3
G
M
M
M
TR
TPs
HATS
24
26
HPS
HPR 3
3 PHASE WIRING DIAGRAM
OL
T4
OL
T5
M1
T6
OL
OL
T1
OL
T2
M2
T3
OL
POWER ON
HOUR
METER
M
TR
5
7
INLET
VALVE
HATR
13
14
HPR
R
TR
FAN
MOTOR
COMP
MOTOR
w

Publicidad

Tabla de contenido
loading

Tabla de contenido