Testing Of The Appliance; Adjustments - Angelo Po FX 61 E3 Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

5 – Replace the guard (G).
6 – Replace the panel (A) and screw the screws back into place.
7 – Remove the test voltage indicator sticker from the dataplate (L) and apply the new
one to identify the voltage being used
Important
On completion of the operation make sure that there are no malfunctions.

TESTING OF THE APPLIANCE

Important
Before it is put into service, the system must be tested to check the operating
conditions of every single component and identify any malfunctions. In this
stage, it is important to check that all health and safety requirements have been
complied with in full.
To test the system, make the following checks.
1 – Turn on the water supply tap and make sure that the connection is watertight.
2 – Turn on the master switch to check the electrical connection.
3 – Make sure that the mains voltage is the same as that of the appliance and, if nec-
essary, carry out the conversion (see page 56).
4 – Check the water pressure and adjust if necessary (see page 58).
5 – Check that the safety device is operating correctly.
6 – Carry out a cooking cycle without food to ensure that the appliance is operating
correctly.
After testing, if necessary instruct the user in all the skills necessary for putting the ap-
pliance into operation in conditions of safety, in accordance with legal requirements.
RECOMMENDATIONS FOR ADJUSTMENTS
Important
Before making any type of adjustment, activate all the safety devices provided
and decide whether staff at work and those in the vicinity should be informed.
In particular, turn off the water supply tap, cut off the electricity supply using the
master switch and prevent access to all devices that might cause unexpected
health and safety hazards if turned on.