14.4.2 Start (for ZI-STE8000 and ZI-STE8004)

To start the generator, proceed as follows:
 Ensure that the generator is in a perfect condition.
 When there are some devices connected with the AC sockets you
have to disconnect them.
 Open the fuel tap.
 Starting the generator with the remote control or with the start key
Key: Turn the key to the „START" position.
Only in an emergency (insufficient battery load), the generator can also be started by
recoil starter. To do so: The throttle valve must be operated manually (= choke), for
starting close the throttle valve (position 0) after start open the throttle valve again
(position I). It is necessary to disassemble the side guard.
Disassemble the side guard

14.4.3 Stop

 Turn off connected equipment and disconnect from the socket.
 To turn off the generator, move the power switch simply to the OFF position.
 Close the fuel tap.
ZIPPER MASCHINEN GmbH
ZI-STE2800; ZI-STE5500; ZI-STE800; ZI-STE8004
www.Zipper-Maschinen.at
Remote control
Press the „START" button
Throttle valve to position 0 for starting. To
Pos. I during operation.
OPERATION
40