Extract: For details, see the Instructions for Use/data sheets for the sensors used
DrägerSensor
Measuring principle
Measurement value configuration time t
for methane
for propane
Measurement value configuration time t
for methane
for propane
Measuring range
Zero error (EN 45544)
Instrument drift
Warm-up time
Effect of sensor poisons,
Hydrogen sulphide H
S, 10 ppm:
2
halogenated hydrocarbons, heavy metals,
gases containing silicone, sulphur or
polymerizable substances
Measuring accuracy [% of the measured value]
Standards
(Measuring function for explosion protection
and measurement of oxygen deficiency and
surplus as well as toxic gases, EXAM,
Essen, Germany:
BVS 08 ATEX G 002 X), PFG 08 G 001
Cross sensitivities
1)
The Technical Handbook and Instructions for Use/data sheets for the sensors used and the PC software CC-Vision for Dräger X-am 5600 are available on CD. See also attached Instructions for Use and Data
Sheets of the sensors used. The Instructions for Use/data sheets for the sensors used can also be downloaded at the following Internet address: www.draeger.com
2)
The instrument responds to most combustible gases and vapours. The sensitivities differ depending on the type of gas. We recommend a calibration using the target gas to be measured.
3)
The measuring signals can be affected additively by sulphur dioxide and nitrogen dioxide and negatively by chlorine.
4)
The measuring signals can be affected additively through acetylene, hydrogen and nitrate monoxide.
5)
Certified for 1 to 100 ppm.
6)
Certified for 3 to 500 ppm.
7)
A table of the cross sensitivities is contained in the Instructions for Use or the data sheet of the respective sensor.
8)
For methane, propane and ethylene.
XXS O
2
electrochemical
electrochemical
d 10 seconds
0..0.90
d 6 seconds
0...50
0 to 25 vol. %
0 to 200 ppm H
– – –
d 1 % of the measured
– – –
d 5 minutes
– – –
d 1
EN 50104
EN 45544-1
(measurement of
oxygen deficiency
and oxygen surplus)
EN 50271
7)
exist
1)
XXS H
S
XXS CO
2
electrochemical
d 15 seconds
d 25 seconds
d 6 seconds
d 6 seconds
5)
S
0 to 2000 ppm CO
2
2 ppm
6 ppm
d 1 % of the measured
value/month
value/month
d 5 minutes
d 5 minutes
– – –
– – –
d 2
d 2
3)
EN 45544-1
EN 45544-2
EN 45544-2
EN 50271
EN 50271
7)
7)
exist
exist
2)
Dual IR Ex
2)
IR Ex
infrared absorption
d 20 seconds
d 20 seconds
d 25 seconds
d 15 seconds
d 10 seconds
d 15 seconds
6)
0 to 100 %LEL
0 to 5 vol.-%
or
8)
0 to 100 vol.-%
– – –
– – –
d 3 minutes
– – –
d 3,5
4)
– – –
7)
exist
Dual IR CO
2
IR CO
2
infrared
– – –
– – –
d 3 minutes
– – –
d 3,5
– – –
7)
exist
21