Installation instructions

The installation must be carried out by qualified personnel to ensure
that the appliance is connected in accordance with safety regulations.
In rooms with showers and bath tubs the appliance must be installed
with the minimum distances laid down in the VDE regulations (0.6 mtrs
(24 inches) from the edge of the shower and/or bath and 1.2 mtrs (48
inches) from a shower head).

Installation sequence

The maintenance-friendly installation concept
The TT1800 installation system enables simple, maintenance-friendly
wall mounting without having to open up the appliance. For ease of
installation, we have separated the appliance into two components:
The installer installs a socket (or a permanent connection), screws the
mounting plate on, slides the ready-to-use appliance onto it, inserts the
mains plug into the socket (or connects), screws the anti-theft cover plate
on – finished. It's as easy as that!
1.
Pull the cover plate [ 1 ] (not screwed on) down and out of the
appliance. Pull the mounting plate [ 2 ] which has been inserted
at the back of the appliance downwards and out.
.
Confirm where the appliance is to be located, mark the 4 fixing
�ole� [ 12 ], using mounting plate [ 2 ] as a template, drill the
holes (8 mm Ø), insert the dowels and fix the mounting plate
with the enclosed button-head wood screw A. We recommend
mounting heights as shown in figures A, B or C. It must be
ensured that the appliance is firmly secured to a solid wall.
.
There are 5 different ways to connect the appliance as
described below.
a)
Mounting via an installed flush socket.
The upper part of the cover plate [ 1 ] i� not required. Break
it off at the predetermined breaking point [ 4 ]. W�en t�e
mounting plate [ 2 ] has been fixed, push the appliance onto to
the mounting plate from the top as shown in figure B , in�ert
the plug into the socket [ 3 ] und push the appliance all the way
down. Fasten the cover plate with the 2 enclosed countersunk
flat head tapping screws.
�)
Concealed wiring
Connection via wiring concealed in the wall [ 7 ](in�tead of a
socket). Fix mounting plate [ 2 ] to wall as shown in fig. C. Slide
the cover plate into the mounting plate from below and route
the wiring from the wall through the opening in the cover plate.
Insert the attached terminal [ 11 ]. Cut the plug at the connection
lead [ 5 ] of the appliance, strip the cable and, squeeze the wire
end ferrules on. Connect both lead as shown in fig. C. Ensure
t�at L (brown) and N (blue) are connected correctly. Secure t�e
connecting lead of the appliance with the enclosed strain-relief
clamp [ 8 ]. Push appliance fully down onto the cover plate and
screw in the 2 enclosed countersunk flat head tapping screws.
c)
Surface mount wiring from above
Break out the wiring lead through at the rear of the appliance,
top centre. When the mounting plate [ 2 ] �a� �een attac�ed a�
shown in fig. C, route the surface mount wiring on the mounting
plate down under the cover plate [ 1 ] and through the opening.
Continue with the connection as described in the 2nd paragraph
under B.
...mehr als Sie denken!
d)
Surface mount wiring from below
On the cover plate [ 1 ], bottom centre, break out the wiring lead
t�rou�� [ 9 ]. When the mounting plate [ 2 ] �a� �een attac�ed
as shown in fig. C, route the surface mount wiring through the
opening in the cover plate. Continue with the connection as
described in the 2nd paragraph under B.
e)
Connecting lead with plug.
Connection to a nearby socket with a flexible connecting lead
with plug. On the cover plate [ 1 ], �ottom centre, �reak out t�e
wiring lead through [ 9 ]. Slide the cover plate into the mounting
plate from below. Insert the attached terminal [ 11 ]. Cut the plug
at t�e connection lead [ 5 ] of the appliance, strip the cable and,
squeeze the wire end ferrules on. Prepare the connecting lead
with the plug in the same way and route through the opening in
the cover plate. Connect both wires as shown in fig. C and �e-
cure with the enclosed strain relief clamps [ 8 ]. Push appliance
fully down onto the cover plate and screw in the 2 enclosed
countersunk flat head tapping screws.
The appliances are now operational.
Switching options
Operate electronic timer switch on TT 1800 and TTH 1800. T�e time
delay for TT 1800 i�  �ec�. and, for TT 1800 E,  min�.
The appliances will switch off automatically.
TT 1800 E, TTH 1800 E Active Oxygen / scent, TTH1800 E
The appliances are operated without touching via infrared proximity
switches.
The switching distance (distance between the underside of the appli-
ance and hands and/or head) is approx. 15 cm (6 inches) for the TT
1800 and approx. 40 cm (16 inches) for the TTH 1800 E. The switching
�en�itivity can �e c�an�ed �y a tec�nician.
Safety cut-out sensor
TT 1800 E, TTH 1800 E
The integrated electronics prevent continuous operation if the infrared
proximity switch has been covered, e.g. due to chewing gum vandalism
TT 1800 E-models will switch off after 4 mins and TTH 1800 E model�
after 10 min�. After t�e �ource of interference �a� �een removed, t�e
dryers are operational again.
18

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Airstar tt 1800eAirstar tth 1800Airstar tth 1800e

Tabla de contenido