PROBLEM
Engine will not start.
Engine hard to start.
Engine lacks power.
Electric start feature not working.
AC receptacle does not work.
Smell of propane gas.
Gas leak detected from cylinder, regula-
tor, or other connection.
Humming noise from regulator.
If problem persists after trying the above solutions, contact customer service or a qualified service center for assistance.
NOTICE:
As the equipment owner, you are responsible for the performance of the required maintenance listed in the Maintenance
section It is recommended that you retain all receipts covering maintenance on your equipment. Neglecting or failing
to perform the required maintenance may increase emissions, decrease fuel efficiency, degrade performance, cause
irreversible engine damage and/or void your warranty.

TROUBLESHOOTING

POSSIBLE CAUSE
Lubricant level is low.
Spark plug faulty, fouled, or improp-
erly gapped.
Propane cylinder is empty.
Vapor lock at coupling nut to propane
cylinder.
Choke lever is in RUN position.
Engine is cold and needs to be primed.
Weak spark at spark plug.
Air filter element clogged.
Engine switch is in OFF ( O ) position.
Battery wires are disconnected.
Battery is not charged.
Circuit breaker is tripped.
GFCI is tripped.
Item plugged in is defective.
Propane cylinder valve open.
Hose or valve leaking.
Improper installation and loose
connections.
Mechanical failure due to rusting or
mishandling.
Cylinder valve turned on too quickly.
Page 22 — English
SOLUTION
Engine is equipped with Low Oil Shutoff.
If engine lubricant level is low, it must be
filled before unit will start. Check engine
lubricant level and fill, if necessary.
Replace spark plug.
Replace or refill propane cylinder.
Turn off generator and close cylinder
valve.
Move choke lever to START position.
Press primer button one time.
Replace spark plug or contact a quali-
fied service center.
Check air filter element. Clean or replace
as needed.
Turn engine switch ON ( I ).
Connect the battery wires.
Charge the battery.
Reset the AC circuit breaker.
Reset the GFCI.
Try a different item.
Turn off cylinder valve immediately and
tighten connections.
Turn off cylinder valve immediately
and check for damaged hose or valve.
Perform leak test; see Testing Cylinder
Connection for Leaks in the Assembly
section.
Tighten fittings and see Testing Cylinder
Connection for Leaks in the Assembly
section.
Replace or refill propane cylinder.
Turn off generator and close cylinder
valve. Turn valve on slowly.

Publicidad

loading