• Factory OFF
The purpose is to return the welding machine to the
original default settings.
To access the function, simply highlight it using the
knob B. By pressing this for less than 2 seconds, the
display screen A shows the words OFF and ALL. By
highlighting the word ALL and briefly pressing the knob
B reset is made and the display screen A shows Factory
Done!! This indicates the reset has been successful. To
return to the previous display page, simply press the
knob B for more than 2 seconds.
NOTE. For all the functions adjusted by means of the
adjustment bar, the initial default value can be reset.
This operation be performed by pressing the knob B
for more than 2 seconds only once the adjustment bar
appears on the display screen A.
(Arc Length - Spot Time - Pause Time - Inductance,
Burnback – Soft Start).
8 MAINTENANCE
All
maintenance
jobs
professional personnel according to the CEI 26-29
(IEC 60974-4) standard.

8.1 GENERATOR MAINTENANCE

In case of maintenance inside the appliance, make sure
the switch F is in "O" position and that the power supply
cable is disconnected from the mains.
Periodically, also clean the inside of the appliance and
remove any metal dust using compressed air.
8.2
HOW TO PROCEED AFTER MAKING REPAIRS.
After making repairs, always ensure the wires are fully
insulated between the primary side and the secondary
side of the machine. Avoid the wires coming into contact
with moving parts or parts that heat up during operation.
Fit all the clamps back as on the original machine so as to
avoid any contact between the primary and secondary in
case of accidental lead breakage or disconnection.
Also fit the screws back on with the toothed washers as
on the original machine.
must