• Time Stamp for the Energy
Integrator.
• Auto Ranging with Manual Ranging
Capability.
• MAX/MIN Record Mode.
• Data Hold.
• Low Battery Indicator.
• Auto Power-off after 20 minutes
inactivity in any measurement
function just except the MIN/MAX
RECORD mode and the Energy
Integrator mode.
• Frequency Response Range : 45 Hz
to 450 Hz.
8.2 General specifications
Display:
4 digit LCD for power 6 digit
LCD for energy A/D.
Conversion Rate:
Approx. 4 times/sec for digital.
Max Volts to Ground:
Max Current:
700A RMS.
Overflow Indication:
LCD will show an "OFL".
Low Battery Indication:
displayed when the battery voltage
drops below the operating voltage.
Battery Life:
80hours typical (alkaline).
Battery Type:
NEDA 1604A 9V or
6LF22 9V.
Maximum Conductor Size:
ø51mm (2,00").
Maximum Jaw Opening:
52mm (2,04").
Maximum Conductor Voltage:
600V RMS.
Adjacent Conductor Effect:
current in adjacent conductor (Max.).
Indoor-use Altitude: 2,000m.
Operating
Temperature
Humidity:
0°C to 50°C (32°F to 122°F)
at R.H.< 80% non-condensing.
Pollution degree:
600V RMS.
The
is
1.5% of
and
2
E N G L I S H
Safety Conformance:
the requirements of UL 3111-1, CSA
C22.2 No.1010.1-92 and ANSI/ISA–
S82.01-94.
Weight:
Approx. 545g (1.21 lb).
Size:
4.39 cm (H) x 9.75 cm (W) x 24.5
cm (L) ( 1.73" H x 3.84" W x 9.65" L).
Standard Accessories:
instruction manual, test leads and
clip-on holster.
Conforms to
Battery (9V),