in the pump as a result of internal circu-
lation.
Through this the pump and the connec-
tion lines can become damaged or
leaky, allowing hot water to escape.
Danger of scalding!
Do not operate the pump against a
closed pressure line for longer than
5 minutes.
Unplug the pump and allow to cool.
A specialist must check the system
to make sure it is in perfect working
order before it can be used again.
B
Danger! Risk of electric
shock!
Do not direct water jet directly
against the pump or other electrical
parts! Risk of fatal electric shock!
Do not touch the plug with wet
hands! To unplug always pull on the
plug, not the power cable.
The earthed outlet or the plug con-
nection to an extension cable must
be located in an area safe against
flooding.
Use only extension cables of suffi-
cient lead cross section (see "Tech-
nical Specifications"). Unroll cable
reels fully.
Do not buckle, squeeze, drag or
drive over power cable or extension
cables; protect from sharp edges,
oil and heat.
Place extension cable so that it can
not get into the fluid to be pumped.
Unplug:
– prior to all servicing;
– when persons are in the swim-
ming pool or garden pond.
A
Hazard generated by tool de-
fects!
If you notice transport damage while
unpacking, notify your supplier im-
mediately. Do not operate the
pump!
Before each use check the pump,
especially the power cable and plug
for possible damage. Risk of fatal
electric shock!
A damaged pump must be work-
manlike repaired before it can be
used again.
Do not attempt to repair the pump
yourself! Only trained specialists are
permitted to service or repair pumps
or pressure vessels.
A
General hazards!
Do not operate the pump if anyone is in
contact with the pumping media (e.g. in
the swimming pool or garden pond)!
A
Caution! 
To avoid water damage, e.g. flooded
rooms, caused by pump malfunc-
tions or defects:
provide for suitable safety measures
such as the following:
– alarm or
– collection tank with monitoring.
The manufacturer is not liable for any
damage caused by:
– improper use of the pump;
– overloading of the pump through
continous operation;
– failure to operate and store the
pump in a frost-free environment;
– unauthorised modification of the
pump (repairs to electrical equip-
ment may only be carried out by
qualified electricians!);
– use of spare parts which have not
been tested and approved by the
manufacturer; or
– use of unsuitable installation materi-
als (fittings, connection lines etc.).
Suitable installation materials:
– pressure-resistant (min. 10 bar)
– heat-resistant (min. 100°C).
5.

Prior to Operation

The pump is easily assembled and con-
nected. 
If in doubt, contact your specialist sup-
plier or a qualified electrician.
ENGLISH
Installing the Hydromat 
5.1
(HWA only)
3
Note:
Before initial operation the Hydromat
must be installed (illustration according
to version).
10
9
12
1. Check to see that the pump is
turned off and the power cord plug
(11) is unplugged.
2. Turn adaptor (9) onto the discharge
port of the pump.
3. Place Hydromat (10) on the adaptor
and secure with the union nut.
4. Adjust Hydromat position so that the
control panel is easily accessible.
5. Plug power cord plug of pump (11)
in the Hydromat's cable socket (12).
5.2

Installation

– The equipment must be placed on a
plane and level surface, suitable of
bearing the weight of the equipment
fully filled with water.
– Um Vibrationen zu vermeiden, sollte
das Gerät auf eine elastische Unter-
lage gestellt werden.
– The installation location should be
well vented and protected from at-
mospheric exposure.
– When operated at garden ponds
and pools the equipment must be
set up safe against flooding and
protected from falling into the water.
Any additional legal requirements
are to be observed.