Generator use
This welding machine can be used at all mains
supplies providing sine-shaped current and voltage
and not exceeding the approved voltage tolerances
stated in the technical data. Motorised generators
observing the above can be used as mains supply.
Consult your supplier of generator prior to connecting
your welding machine. MIGATRONIC recommends
use of a generator with electronic regulator and supply
of minimum 1.5 x the maximum kVA consumption of
the welding machine. The guarantee does not cover
damage caused by incorrect or poor mains supply.
How to connect the gas
Connect The gas hose, which comes from the
intermediary cable, to a gas supply with pressure
regulator (2-6 bar).
(Note: Some types of pressure regulators require an
output pressure of more than 2 bar to function
optimally).
Assembly of the earth cable
The earth cable (negative pole) is fitted to the
inductance outlet wanted (depending on the
dimension of the welding wire). (Pos. 2-3).
Wire feeding
The wire roll combination to the chosen wire diameter
can be seen from the figure page 46. The machine is
delivered with one set of wire rolls etc. as standard.
Other sizes can be delivered. Only parts of the same
colour can be fitted together.
Adjustment of wire brake
The wire brake must ensure that the wire reel brakes
sufficiently quickly when welding stops. The required
brake force is depending on the weight of the wire reel
and the maximum wire feed speed. A brake torque of
1.5-2.0 Nm will be satisfactory for most applications.
Adjustment:
-
Dismount the control knob by placing a thin screw
driver behind the knob and thereafter pull it out
-
Adjust the wire brake by fastening or loosening the
self-locking nut on the axle of the wire hub
-
Remount the knob by pressing it back into the
groove.

CONTROL SWITCHES

1.
Main switch
2.
Inductance output
Recommended wire diameter ø0.6 - 1.0
3.
Inductance output
Recommended wire diameter ø1.2 - 1.6
4.
ON
Lights when the machine has been turned on.
5.
Adjustment of welding voltage
MIG 385x (1 - 12) fine adjustment
MIG 445x (1 - 12) fine adjustment
6.
Adjustment of welding voltage
MIG 385x (1 - 2) coarse adjustment
MIG 445x (1 - 2) coarse adjustment
7. Overheat error
8