How to connect the separate wire feed unit
Connect the rear of the separate wire feed unit to the
machine using an extension cable which contains
cables and hoses for welding positive (pos. 1), control
signals (pos. 2), gas (pos. 3) and cooling water (pos.
4), if a water module is incorporated in the machine.
Adjustment of wire brake
The wire brake must ensure that the wire reel brakes
sufficiently quickly when welding stops. The required
brake force is depending on the weight of the wire reel
and the maximum wire feed speed. A brake torque of
1.5-2.0 Nm will be satisfactory for most applications.
Adjustment:
Dismount the control knob by placing a thin screw
-
driver behind the knob and thereafter pull it out
Adjust the wire brake by fastening or loosening the
-
self-locking nut on the axle of the wire hub
-
Remount the knob by pressing it back into the
groove.

CONTROL SWITCHES

1.
Main switch
2.
Inductance output
Recommended wire diameter ø 0.6 – 1.0
3.
Inductance output
Recommended wire diameter ø1.2 – 1.6
4.
Inductance output
Recommended wire diameter ø1.6 – 1.8
5.
Inductance output
Recommended wire diameter ø1.8 – 2.0
6.
ON
Lights when the machine has been turned on.
7.
Overheat error
8.
Torch cooling error