Placing Tool In Service - Ingersoll Rand 500PS3 Manual De Operación Y Mantenimiento

Ocultar thumbs Ver también para 500PS3:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7. Submerge the mechanism in a reservoir containing
mechanism fluid, and using a wrench, rotate the Drive
Shaft clockwise and counterclockwise to purge any
remaining air from the system.
8. Remove the mechanism from the fluid and rotate the
Adjustment Screw clockwise until it stops.
9. Thread the Oil Plug with the Oil Plug Seal and Seal
Support into the mechanism until it is snug.
10. Wipe the outside of the mechanism dry and clean and
remove the Oil Chamber Plug. Using the syringe,
withdraw 0.55 cc of fluid from 500PS3 models,
0.65 cc of fluid from 700PS3 models and 0.90 cc from
900PS4 models.
11. Install the Oil Chamber Plug and tighten it between 20
and 25 in–lb (2.3 and 2.8 Nm) torque.
12. Position a new Hammer Case Gasket on the Motor
Housing and install the assembled mechanism on the
rotor shaft.
13. Place the Hammer Case Cover over the Drive Shaft
against the Housing and Gasket. Install the three
LUBRICATION
Ingersoll–Rand No. 50
Always use an air line lubricator with these tools.
We recommend the following Filter–Lubricator–Regulator
Unit:
For USA – No. C28–04–FKG0–28
After each 20 000 cycles, or as experience indicates, drain
and refill the Impulse Unit Drive Assembly as instructed
in this manual using the Fluid Replacement Kit (Part
No. EQ106S–K400). Lubricate the hex drive and the output
shaft before assembly.
ADJUSTMENTS
(Dwg. TPD1265)

PLACING TOOL IN SERVICE

Ingersoll–Rand No. 67
Ingersoll–Rand Fluid Part
No. EQ106S–400–1
Hammer Case Cap Screws and Lock Washers. Tighten
each Screw between 45 an 50 in–lb (5.1 and 5.6 Nm)
torque.
14. Test the tool for torque at maximum, minimum and
mid–range torque settings. If the tool does not perform
satisfactorily, repeat the refill procedure and pay
particular attention to removing unwanted air from the
fluid system. Refer to the section TORQUE
ADJUSTMENT for specific adjustment procedures.
15. If the torque is satisfactory but the tool fails to
shut–off, only then, is it necessary to adjust the
shut–off mechanism. If it should become necessary,
proceed as follows:
a. Remove the Adjusting Hole Plug from the
Hammer Case.
b. Using a pointed probe, pick the paint out of the
wrench opening in the Adjustment Screw that
is 180 degrees away from the Torque Adjustment
Screw.
c. Rotate the Screw counterclockwise not more than
ten degrees.
Before operating the tool, mark the shut–off
Adjustment Screw with a permanent marker or
paint so that it can be distinguished for future
adjustments.
d. Permanently mark the Screw for future
identification and the retest the tool. Adjustments
to the shut–off mechanism should only be made in
five to ten degree increments.
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
TO
AIR
SYSTEM
TO
AIR
TOOL
LUBRICATOR
REGULATOR
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
3
FILTER
COMPRESSOR
(Dwg. TPD905–1)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

700ps3900ps4

Tabla de contenido