5.2.1 Functions in the 4-channel mode
DMX Value Function
Channel 1: Proportion of red for segments
0 – 255
brightness of red
Channel 2: Proportion of green for segments
0 – 255
brightness of green
Channel 3: Proportion of blue for segments
0 – 255
brightness of blue
Channel 4: Dimmer and stroboscope for segments
0 – 127
dimmer
128 – 227
stroboscope: slow
228 – 255
max. brightness, stroboscope off
5.2.2 Functions in the 12-channel mode
DMX Value Function
Channel 1: Proportion of red for segment
0 – 255
brightness of red
Channel 2: Proportion of green for segment
0 – 255
brightness of green
Channel 3: Proportion of blue for segment
0 – 255
brightness of blue
Channel 4: Dimmer and stroboscope for segment
0 – 127
dimmer
128 – 227
stroboscope: slow
228 – 255
max. brightness, stroboscope off
Channel 5: Proportion of red for segment
0 – 255
brightness of red
Channel 6: Proportion of green for segment
0 – 255
brightness of green
Channel 7: Proportion of blue for segment
0 – 255
brightness of blue
Channel 8: Dimmer and stroboscope for segment
0 – 127
dimmer
128 – 227
stroboscope: slow
228 – 255
max. brightness, stroboscope off
Channel 9: Proportion of red for segment
0 – 255
brightness of red
Channel 10: Proportion of green for segment
0 – 255
brightness of green
Channel 11: Proportion of blue for segment
0 – 255
brightness of blue
Channel 12: Dimmer and stroboscope for segment
0 – 127
dimmer
128 – 227
stroboscope: slow
228 – 255
max. brightness, stroboscope off
,
,
,
,
,
,
,
,
fast
fast
fast
fast

5.3 Switching off the display

If no button (6, 7) has been pressed for approx.
30 s, the display (8) will be switched off automati-
cally. To switch it on again, press a button. The
adjustments will not be changed by this first press
of a button.
5.4 Key lock
The buttons (6, 7) may be locked against acciden-
tal operation. For this purpose keep the button
MODE (6) pressed for 3 s as a minimum. The dis-
play (8) now shows alternately
ating mode and the adjustments of the unit cannot
be changed any more.
To release the key lock, press the button MODE
for 3 s as a minimum.

6 Cleaning of the Unit

The plastic pane in front of the LEDs should be
cleaned from the outside at regular intervals,
depending on impurities caused by dust, smoke or
other dirt particles. Only this will ensure that the
light is radiated at maximum brightness. For clean-
ing, disconnect the mains plug from the socket.
Only use a soft, clean cloth and a mild detergent.
Then wipe the pane dry.
For cleaning the other parts of the housing, only
use a soft, clean cloth. Never use any fluid; it may
leak into the unit and cause damage.
7 Specifications
Light source: . . . . . . . 252 LEDs (63 red,
diameter: . . . . . . . . 10 mm
beam angle: . . . . . . 30°
Power supply: . . . . . . 230 V~ / 50 Hz
Power consumption: . 45 VA max.
Current rating of
the mains output jack: 8 A max.
Ambient temperature: 0 – 40 °C
Dimensions: . . . . . . . . 1064 × 66 × 64 mm
Weight: . . . . . . . . . . . . 1.9 kg
Subject to technical modification.