Cleaning Of The Optical System - IMG STAGELINE LE-350WAV Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
1) Unscrew the screws (2) for the lamp compartment
cover. Remove the cover. The lamp support is in
the compartment (fig. 3).
2) Insert the halogen lamp into the support and push
on the lamp connection (fig. 4). Pay attention that
the lamp is centred in the support.
3) Reposition the cover and tighten the screws (2).
5 Mounting
The unit can be placed on a firm, even, heat-resistant
surface. However, it can also be suspended from a
crossbar via its mounting bracket (1).
IMPORTANT
Always place the unit so that a sufficient air ventila-
tion is ensured during operation.
The unit must have a minimum distance of 50 cm
to adjoining surfaces and the air vents at the hous-
ing must not be covered in any case.
Pay in any case attention to a sufficient distance to
easily flammable material or material sensitive to
heat.
To align the unit, release the two setscrews (4) at the
mounting bracket. Adjust the desired inclination of the
unit and retighten the screws.
WARNING
The unit must be mounted in a safe
and expert way. If it is installed as a
suspended load above persons, it
must additionally be secured (e. g. by
a safety rope at the mounting bracket;
fix the safety rope in such a way that
the maximum falling distance of the
unit is 20 cm).
6 Operation
Connect the mains cable to the mains jack (6) and the
mains plug to a mains socket (230 V~/50 Hz). Thus,
the unit is switched on. To switch off the unit, dis-
connect the mains plug.
For a more convenient operation it is recommend-
ed to connect the unit to a mains socket which can be
switched on and off via a light switch.
All rights reserved by MONACOR
be reproduced in any form or by any means for any commercial use.
6.1 Stopping or continuing the colour change
The colour is changed by means of a rotating colour
wheel inside the unit, the motor of which is switched on
and off via the switch (5). For a certain colour or colour
combination of the projection instead of a permanent
colour change, press the switch when this colour is
reached. To continue the colour change, press the
switch again.
6.2 Focus setting
1) Release the screw (3).
2) By sliding the screw forward and backward, the
3) Retighten the screw.

7 Cleaning of the Optical System

The lens, the colour wheel, and the structural glass
panes should be cleaned at regular intervals, depend-
ing on impurities caused by dust, smoke, or other par-
ticles. Only in this case the light can be radiated at
maximum brightness. Prior to opening the unit, dis-
connect the plug from the mains socket and let the unit
cool down for 15 minutes.
cial detergent for glass. Then carefully wipe the parts
dry.
8 Specifications
Power supply: . . . . . . . . . . . 230 V~/50 Hz
Power consumption: . . . . . . 270 VA
Lamp: . . . . . . . . . . . . . . . . . . reflector halogen lamp
Ambient temperature: . . . . . 0 – 40 °C
Dimensions: . . . . . . . . . . . . . 230 x 150 x 370 mm
Weight: . . . . . . . . . . . . . . . . . 7.5 kg
Subject to technical modification.
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may
lens is moved. Adjust the focal length so that the
presentation on the projected area obtains the de-
sired sharpness.
For cleaning use a soft, clean cloth and a commer-
24 V/250 W, type MR16
with base GX 5,3
GB