7 Specifications
General
Display: . . . . . . . . . . 17 mm LCD, 3
Measuring rate: . . . . 2
Power supply: . . . . . . 9 V battery
Range of application: 0–40 °C, < 70 % air
Battery lifetime: . . . . approx. 30 hours
Dimensions: . . . . . . . 89.5 x 200 x 44 mm
Weight: . . . . . . . . . . . 675 g
Inductivity
Measuring ranges: . . 200 µH, 2 mH,
Accuracy*
200 µH–200 mH: . ±(3 % + 3 digits)
2 H–200 H: . . . . . . ±(5 % + 10 digits)
Measuring frequency
200 µH–2 H: . . . . . 1000 Hz
20 H–200 H: . . . . . 100 Hz
Capacity
Measuring ranges: . . 200 pF, 2 nF, 20 nF,
Accuracy*
200 pF–200 nF: . . ±(1 % + 3 digits)
2 µF–200 µF: . . . . ±(2 % + 3 digits)
2000 µF: ≤ 1000 µF: ±(3 % + 3 digits)
2000 µF: > 1000 µF: ±(5 % + 10 digits)
Measuring frequency
200 pF–2 µF: . . . . 1000 Hz
20 µF–200 µF: . . . 100 Hz
2000 µF: . . . . . . . . 10 Hz
1
/
-digit
2
1
/
measurements/
2
sec.
humidity
(carbon-zinc battery)
20 mH, 200 mH,
2 H, 20 H, 200 H
200 nF, 2 µF, 20 µF,
200 µF, 2000 µF
Resistance
Measuring ranges: . . 20 Ω, 200 Ω,
Accuracy*
20 Ω: . . . . . . . . . . . ±(1 % + 10 digits)
200 Ω: . . . . . . . . . . ±(0.3 % + 3 digits)
2 kΩ–2 MΩ: . . . . . ±(0.3 % + 1 digit)
20 MΩ: . . . . . . . . . ±(2 % + 2 digits)
Diode test
Display: . . . . . . . . . . forward voltage with
Accuracy*: . . . . . . . . ±(10 % + 10 digits)
*at 23 °C, ±5 °C
According to the manufacturer.
Subject to change.
2 kΩ, 20 kΩ, 200 kΩ,
2 MΩ, 20 MΩ
3 mA test current,
Zener diodes up to
6.8 V