Special programming - Art. 4680K
-V
1
3
5
6
1622
4680
4680K
4680C
4680KC
+V
2
Set the dip switches in accordance
with the function you wish to
program, see table on page 17
1622
4680
4680K
4680C
4680KC
4
1 sec.
⇒
optional
optional
7
Dip switch
Code
ON
De-misting heating element
213
1,3,5,7,8
OFF (default)
212
3,5,7,8
ON
Audio-visual messages
210
2,5,7,8
visual messages only
211
1,2,5,7,8
Swedish
214
2,3,5,7,8
OFF (default)
215
1,2,3,5,7.8 Italian
216
4,5,7,8
French
217
1,4,5,7,8
Spanish
218
2,4,5,7,8
Dutch
219
1,2,4,5,7.8 Greek
220
3,4,5,7,8
English
221
1,3,4,5,7.8 German
222
2,3,4,5,7.8 Portuguese
Door lock
223
1,2,3,4,5,7,8 Door lock command on SE in AC (default)
224
6,7,8
Door lock command on SE in enhanced AC
225
1,6,7,8
Door lock command on SE in DC
Door lock time: 2 sec. + disabling tone
245
1,3,5,6,7.8
(default)
246
2,3,5,6,7.8 Door lock time: 4 sec.
247
1,2,3,5,6,7,8 Door lock time: 8 sec.
248
4,5,6,7,8
Door lock confirmation tone: enabled
251
1,2,4,5,6,7,8 C.NC.NO relay in parallel with SE (default)
252
3,4,5,6,7.8
253
1,3,4,5,6,7,8
Actuator control management
NOTE the system should not include Art.
1256 in generic actuator mode.
Enabling
C.NC.NO
229
1,3,6,7,8
control: 2 sec.
Enabling
C.NC.NO
230
2,3,6,7,8
control: 4 sec.
1,2,3,6,7.8 Enabling
C.NC.NO
231
control: 8 sec.
Actuator function on S serial line = disabled
228
3,6,7,8
(default)
227
1,2,6,7,8
Actuator function on S serial line = enabled
System functions
232
4,6,7,8
Awaiting response time: 60 sec. (default)
233
1,4,6,7,8
Awaiting response time: 180 sec.
234
2,4,6,7,8
Awaiting response time: 30 sec.
235
1,2,4,6,7.8 Talk time: 90 sec. (default)
236
3,4,6,7,8
Talk time: 180 sec.
237
1,3,4,6,7.8 Self-ignition: enabled (default)
238
2,3,4,6,7.8 Self-ignition: disabled
Confirmation tone on user call = enabled
239
1,2,3,4,6,7,8
(default)
240
5,6,7,8
Confirmation tone on user call = disabled
243
1,2,5,6,7.8 Reset wait time: 10 sec. (default)
244
3,5,6,7,8
Reset wait time: 1 sec.
Reset after lock-release in audio: enabled
208
5,7,8
(default)
209
1,5,7,8
Reset after lock-release in audio: disabled
249
1,4,5,6,7.8 Call transmission: single (default)
250
2,4,5,6,7.8 Call transmission: triple
254
2,3,4,5,6,7,8
Restore default
relay
on
actuator
relay
on
actuator
relay
on
actuator
17
17