English
Attach to the tip of the push lever in the reverse
order of detaching.
Nose cap
NOTE:
The information contained in this Manual is
designed to assist you in the safe maintenance of
the Stapler.
Some illustrations in this Manual may show details
or attachments that differ from those on your own
Stapler.
MAINTENANCE AND INSPECTION
Read section titled "SAFETY" (pages 4 – 6).
WARNING
Disconnect air hose and remove all
staples from Stapler when:
1)
doing maintenance and inspection;
and
2)
clearing a jam.
1.
Clearing a jam
Remove a jammed staple in the following order:
1 DISCONNECT AIR HOSE.
2 Remove all staples.
3 Release the lock lever and open guide plate.
16
1
Disconnect
air hose
Firing head
Push lever
MAINTENANCE
3
Lock lever
3
Guide plate
4 Remove the jammed staple with a slotted-
head screwdriver.
Guide plate
5 Close guide plate and latch.
6 In case of frequent jam, contact a Hitachi
authorized service center.
1
Disconnect
air hose