Device Specification; Process Data - Balluff BIP LD2-T -03-S75 Serie Manual De Instrucciones

Ocultar thumbs Ver también para BIP LD2-T -03-S75 Serie:
Tabla de contenido

Publicidad

BIP LD2-T_ _ _-03-S75
Inductive Positioning System
6
IO-Link interface (continued)
6.2

Device specification

Specification
Transfer rate
Minimum cycle time of device
Frame specification
– Amount of preoperate data required
– Amount of operate data required
– Enhanced parameters
IO-Link protocol version
Amount of process data
from the device to the master
Amount of process data
from the master to the device
Manufacturer ID
Device identification
Tab. 6-1:
Device specification
Transfer times
Process data cycle with 1.0/1.1 master
Tab. 6-2:
Device transfer times
6.3

Process data

The BIP outputs 2-byte process data via the IO-Link
interface. These comprise the left-aligned 12-bit position
value and 4 binary values.
Octet 0
7
6
5
4
(MSB)
OoR1
1)
1
outside the measuring range
0
within the measuring range
Target out of range
1)
reserved
2)
Tab. 6-3:
Process data
www.balluff.com
IO-Link Description
COM2
min cycle time
M-sequence capability:
– Preoperate M-sequence type
– Operate M-sequence type
– ISDU supported
Revision ID
ProcessDataIn
ProcessDataOut
Vendor ID
Device ID
master cycle time = 3 ms
3
2
1
0
Position value
Target
Value
38.4 kBaud
0x1E (3 ms)
0x1B
2 bytes
1 bytes
Supported
0x11 (Version 1.1)
0x10 (2 bytes)
0x00 (0 bits)
0x378
0x020305 (BIP LD2-T048)
0x020306 (BIP LD2-T070)
0x020307 (BIP LD2-T103)
0x020308 (BIP LD2-T133)
Octet 1
7
6
5
4
(LSB) OoR
3
2
1
0
1)
2)
2)
2)
english