INSTALLATION / HANDLING
ELECTRICAL DATA – ALL UNITS UP6–30 / UP6 25–HA
Standard voltage
Drive motor
Motor enclosure
Power
Full load current (max) / HA
Starting current DOL (STAR)
Starting time DOL (Star Delta)
Starts per hour (maximum)
ELECTRICAL DATA DOL / Star Delta
Control voltage
Minimum fuse rating
See note 1
Minimum wire size AWG
See note 2
1. If a circuit breaker is selected it should only be a magnetic trip type,
set above the anticipated starting current of the machine, but below the
maximum prospective fault current for the circuit. The circuit breaker
or fuseable disconnect must be capable of breaking the prospective
fault current at its terminals.
2. PVC/PVC Type Calculated using the following conditions:
i) PVC insulated cable, armoured, copper conductors.
ii) Cable clipped to a wall, in free air.
iii) Ambient temperature of 40_C (104_F) and relative humidity of 40%.
iv) 20m (65ft) cable run.
v) Volt drop limited to –10% during starting, –4% during normal
running.
vi) Protected by the circuit breaker listed above.
If there are any deviations from the above, or special regulations
apply, the installation must be planned by a competent, qualified
engineer.
NOTE
All data applies to standard product only.
ELECTRICAL DATA
An independent electrical isolator or disconnect should be installed
adjacent to the compressor.
200V
ODP
TEFC
ODP
91.3/80.8A
91.9/79.8A
79.3/70.3A
500 (216.7)
434 (188.4)
150A
1
230V
380V
TEFC
ODP
30HP
79.9/69.4A
48.1/42.6A
48.4/42.0A
263 (114)
3–5 Sec ( 7–10 Sec)
6
120VAC
125A
80A
2
4
Feeder cables/wires should be sized by the customer/electrical
contractor to ensure that the circuit is balanced and not overloaded by
other electrical equipment. The length of wiring from a suitable
electrical feed point is critical as voltage drops may impair the
performance of the compressor.
Feeder cables / wires connections to isolator or disconnect should
be tight and clean.
The applied voltage must be compatible with the motor and
compressor data plate ratings.
The control circuit transformer has different voltage tappings.
Ensure that these are set for the specific applied voltage prior to
starting.
CAUTION
Never test the insulation resistance of any part of the machines
electrical circuits, including the motor without completely
disconnecting the electronic controller (where fitted).
CAUTION
Ensure that the motor rotates in the correct direction as
indicated by direction arrows, and on drawing.
460V
TEFC
ODP
TEFC
39.7/35.2A
40.0/34.7A
217 (94.2)
60A
6
575V
ODP
TEFC
31.7/28.1A
32.0/27.8A
169 (75.4)
50A
8