Repair
If despite strict observance of the manufacturing and
testing method the tool should happen to fail, it must be
repaired by an authorized PFERD agency.
SPECIFIED CONDITIONS OF USE
The tool is designed for grinding, milling and deburring
metal, stone and plastic with milling cutters and abrasives.
Do not use this product in any other way as stated for
normal use.
CONNECTION TO THE COMPRESSED AIR
SUPPLY
Only connect the machine to an oil compressed air supply.
Unoiled compressed air will increase wear and reduce the
machine's service life.
Check the compressed air before you connect the
machine to the compressed air supply. The pressure must
not exceed the maximum pressure specifi ed on the model
plate and in this operating manual
Set the valve to the „Off" position before you connect the
machine to the compressed air supply.
Always set the valve to the „Off" position before you
break the compressed air supply to prevent unintended
activation.
Use a conditioning unit consisting of a fi lter, pressure
regulator and oiler.
Inhaling oil mist may be harmful. Use only approved lubri-
cants (see also air quality in the section entitled Technical
data).
Contaminated compressed air will reduce the machine's
service life. You should therefore blow through extension
hoses, for example, before you connect them. Do not use
valve couplings if possible.
Air supply requirements:
The ISO/DIS quality specifi cations require, that air is free
of solid particles larger than 5 micron, remaining water
content to be max. 6 g/m³ (pressure dew point +3 degree
C) and air may contain 5 mg/m³ of oil. Therefore please
observe the following:
Operating with dirty air reduces tool life substantially.
Before installing extension hoses, blow them clean and
minimize , if at all necessary coupling and keep them
clean.
WORKING INSTRUCTIONS
The machine will slow down and stop after it has been
switched off.
If the compressed air supply fails, set the valve to the
„Off" position.
Position or secure the workpiece safely on the work
surface.
30
To achieve good results, move the abrasive to and fro ap-
plying gentle pressure.
Excessive abrasive pressure will reduce the machine's
performance and the abrasive's service life.
The machine may only be switched on if the tools have
been installed correctly.
Check tools before use. The tool must be correctly
installed and must turn freely.
Conduct a test for at least 30 seconds without any load.
Do not use damaged, unround or vibrating tools.
PGAS 2/800 E: The machine may only be switched on if
the closure and tools have been installed correctly.
RECOMMENDED ACCESSORIES
Hose grommet with an internal diameter of at least 3
mm. 1/4" conditioning unit consisting of fi lter (capacity
5-8 micron), pressure regulator and oil.
Other accessories with their order numbers are listed in
the PFERD tool manual. Subject to change. Please quote
the machine type and Part No. when making orders for
spare parts.
ACCESSORIES
Do not use accessories which are not specifi cally
designed and recommended by the tool manufac-
turer. Just because the accessory can be attached to your
air-powered tool, it does not assure safe operation.
MAINTENANCE
Keep the machine clean at all times and store it in a dry
place.
Regular maintenance is essential to keep the machine
safe.
Check the idling speed periodically and after all mainte-
nance work.
Even if the machine is still operating perfectly trained per-
sonnel should remove the motor, clean it and check the
slide for signs of wear periodically after approx. 300 - 400
hours of service but at least once per year.
Check the following parts periodically to ensure they are
in good condition:
- Supply air hose and its mountings (torn compressed air
hoses may whip around out of control)
- Spindle
Drawings and spare parts lists for our tool drive units are
available on our homepage at www.pferd.com or can be
requested by sending a mail to info@pferd.com.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that the product
described under "Technical Data" fulfi lls all the relevant
provisions of the directives 2006/42/EC and the following
harmonized standards have been used:
EN ISO 12100
DIN EN ISO 11148
Marienheide, 2013-11-07
Dr. B. Stuckenholz
W. Benna
Production Manager
Product Management Tool Drives
Authorized to compile the technical fi le
August Rüggeberg GmbH & Co. KG,
Hauptstraße 13
51709 Marienheide
WARRANTY
Our guarantee for defects on electric and air grinders as
also the required accessories is exercised in such a manner
that all parts, which have material defects, will either be
repaired or replaced free of charge. Warranty for these
material defect claims shall be valid for a period of twelve
(12) months at the most. This does not apply if longer
periods of time are stipulated by law. The warranty shall
not cover damage caused by improper handling, the use
of spare parts other than our own, or by repairs carried
out in workshops other than our own. Warranty claims
can only be considered, if tool is returned complete. Any
further claims of the orderer, in particular for compensa-
tion for damage not arisen on the goods themselves, shall
be excluded.
CHANGES / ARCHIVING
Subject to change.
Keep these operating instructions in a safe place for
future use.