Selector
2.1.1
Selector
position
OFF/RESET
PROGRAM
MAN
AUTO
Pushbuttons
2.1.2
Key
MODE /
ACK
ENTER
VIEW
EXIT/SHIFT
PROGRAM
START
STOP
Function
The generator is disabled; warnings and lockouts are cancelled. It is possible to
program the parameters.
The card is set for the manual operation of the generator. Push button
the engine,
to stop it and
generator and vice versa.
The card automatically controls starting and stopping of the generator, and the
switchover of the devices if faults are detected in the mains power. In this mode the
pushbutton activates the "TEST" mode; the
activated) or causes an emergency stop of the engine while activating an alarm; if
the generator is started in "TEST" mode, the
switchover of the devices. The remote start of the generator is also possible (by
means of a serial communication channel, a contact or periodically).
Function
"Acknowledges" a fault by silencing the siren. If there is no fault (or if all active faults have
been acknowledged), it changes the page shown by the display.
In the programming mode it is used to access the menus and to enable and confirm a
parameter change. These functions are activated when the pushbutton is released.
Pushed together with the "VIEW" pushbutton, it adjusts the contrast of the display (the
contrast increases or decreases according to which pushbutton is pressed first).
It is used to scroll the sub-page of the display or to temporarily hide the second row of faults
on the display itself (in order to display the values).
It is used to enter/exit the programming mode, to exit the menus and to cancel the current
setting of a parameter. These functions are activated when the pushbutton is released.
During parameter setting, it is used with
setting.
Pushed together with the
contrast increases or decreases according to which pushbutton is pressed first).
In manual mode it starts the engine.
In automatic mode
it starts a test run of the engine.
In programming mode it is used to scroll through the sub-menu and parameters, and also to
increase the value of a parameter during the setting phase.
It is used to stop the engine, in both manual and automatic modes (in automatic mode it
causes a lockout even if the engine is stopped); if a "TEST" run is ongoing, it is stopped.
In programming mode it is used to scroll through the sub-menu and parameters, and also to
decrease the value of a parameter during the setting phase.
to switch the devices from the mains to the
and
to increase the speed of parameter
"MODE" pushbutton, it adjusts the contrast of the display (the
to start
pushbutton deactivates it (if
pushbutton allows for the
User's Manual DST4400