Before attempting to program any particular
function of the WE-6 microcomputer, read the
System Programming, Cycle Programming,
and Step Programming subsections below.
System Programming
Prompting the WE-6
Prompting the WE-6 allows:
• Displaying sump temperature in
Centigrade or Fahrenheit.
• Recognizing and controlling one
or two independent drains. (Two
independent drains will apply only for
special applications.)
• Enabling or disabling the Advance key
in the RUN mode.
• Enabling or disabling the manual mode.
• Enabling or disabling wet clean functions
(affects Auxiliary 1 and 2 outputs).
• Selecting balancing routine (active if
inverter balance detection is utilized).
• Resetting the cycle count.
To begin prompting the computer, insert key
into the program mode switch (located on the
left side of the control module) and turn key to
the PROGRAM position. The display will
read "CYC00."
1. Press the Auxiliary key, key 2, and
key 9 in that order. The display will read
either "CEN" (Centigrade) or "FAR"
(Fahrenheit). To choose the alternate
feature, press key 0.
2. Press the Enter key. The display will read
either "1DRAIN" or "2DRAIN." The
normal prompt for most applications is
F232050
Programming
"1DRAIN." "2DRAIN" is used only for
special applications. Consult factory for
full details. To choose the alternate feature,
press key 0.
Note: Enabling the second drain via the
Auxiliary 2 output precludes control of the
recirculation pump and is not necessary for the
Premium Wet Clean Module.
3. Press the Enter key. The display will read
either "ADV" or "NO ADV." The prompt
"NO ADV" will disable the Advance key
in the RUN mode, thereby preventing the
operator from advancing the computer
through steps of the cycle before they are
complete; also, it will not be possible to
advance to any step before starting a cycle
if "NO ADV" is selected. To choose the
alternate feature, press key 0.
4. Press the Enter key. The display will read
either "MANUAL" or "NO MAN." If
"MANUAL" is displayed, the manual
mode will be enabled during normal
operation. If "NO MAN" is displayed, the
manual mode will be disabled when a
cycle is run, even if the Manual operation
key sequence is entered. To choose the
alternate feature, press key 0.
5. Press the Enter key. The display will
read either "WET CL" or "NO WCL."
To choose the alternate feature, press
key 0. If "WET CL" is displayed,
wet clean functions are enabled. If
"NO WCL" is displayed, wet clean
functions are disabled.
37