Programming
Cycle Programming

Erasing a Cycle in Memory

1. Insert the key into the program mode
switch (located on the left side of the
control module) and turn the key to the
PROGRAM position. The display will
read "CYC00."
2. Press the Erase Cycle key. The display
will read "ECYC00."
3. Press the two-digit code for the cycle
number that is to be erased. The display
will read "ECYC25" if cycle 25 is chosen.
4. Press the Enter key. The display will read
"WAIT" while it is erasing the cycle. The
display will then return to "CYC00." If
there is no such cycle number in memory,
the display will read "NCYC25." To not
erase a cycle, press the Clear key before
pressing the Enter key. The display will
return to "CYC."
5. Return the program mode switch to the
RUN position and remove the key.

Programming a Wet Clean Cycle

None of the standard 39 preprogrammed cycles
includes wet clean steps. A sample wet clean
cycle is included in Sample Cycles for Modular
Options following the 39 standard cycle charts
near the end of this manual. Review of this
sample cycle will provide some understanding
of the wet cleaning process. The sample cycle is
provided as a model wet clean cycle and is not
intended as a recommendation. However, no
wet clean cycle should be programmed until a
wet clean chemical manufacturer is consulted.
Note: Use of any wet clean cycle prior
to approval by a wet clean chemical
manufacturer's representative can result in
damage to garments.
42
(Continued)

Step Programming

Programming a Fill without Spray

This process is used in temperature-controlled
fill steps where it is desirable to fill without
spray and add water through the sump only.
To program a fill without spray, program a
cold, hot, or warm fill to level as in a normal
fill step; however, instead of pressing the
Enter key after selecting the level, press the
Auxiliary key. The computer will display a
lower case "c," "h," or "w," instead of the
usual upper case "C," "H," or "W." Press the
Enter key now and program the time in the
usual manner.

Programming a Fill Temperature

The table on the next page lists the required
procedures to produce specific results.
The table shows that when HIGH water level is
programmed, the display indicator is "H."
When MEDIUM level is programmed, the
display indicator is "M." When LOW level is
programmed, the display indicator is "L."
When OVERFLOW is programmed, the
display indicator is "O."
When the Warm key is pressed, the next key
pressed will be another temperature key (Hot,
Cold, or Warm) before selecting the level.
Exceptions to this will be when RINSE or
FLUSH steps are used: they require no level
commands, and water is added through the
door spray nozzle only.