Idiomas disponibles

6 Commissioning

6.2.1 Automatic starting

The automatic starting function allows the FEC to be automatically switched on when the welding process starts.Once the
welding process begins, the FEC receives a signal and automatically starts the fume extraction process.
1
Control panel
2
A / Auto button
Fig. 5
Automatic starting
1 Lay the ground cable (4) in the integrated automatic Start-Stop system (6).
2 Connect the ground cable (4) on one end to the power source and on the other end to the welding table, for example.
3 Press the A / Auto button (2) on the control panel.
 5.1 Control elements on page EN-11
The FEC starts automatically when the welding process is started.
6.2.2 Automatic starting functions
Button
I / Power
0 / Error
A / Auto
Tab. 8
Automatic starting functions
EN - 14
1
6
3
Motor protective switch
4
Ground cable
Description
Manual
OFF
Integrated automatic Start-Stop system active (system runs only when welding occurs with a
run-on time of approx. 20 seconds)
2
3
4
5
5
Power cable connector
6
Integrated automatic Start-Stop system
BAL.0533.0 • 2018-10-04