Disposal And Recycling - Stanley DN 200/8/6 Manual De Instrucciones

Ocultar thumbs Ver también para DN 200/8/6:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
compatible manner at the appropriate collection
point.
6.3 Safety valve (ref. 10)
The safety valve has been set for the highest
permitted pressure of the pressure vessel. It is
prohibited to adjust the safety valve or remove its
seal. Actuate the safety valve from time to time to
ensure that it works when required. Pull the ring with
sufficient force until you can hear the compressed
air being released. Then release the ring again.
6.4 Storage
Warning!
Pull the mains plug out of the socket and
ventilate the appliance and all connected
pneumatic tools.
8. POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
FAULT
Leakage of air from the valve
of the pressure switch with
the compressor off.
Reduction of performance.
Frequent start-up. Low
pressure values.
The compressor stops and
restarts automatically after a
few minutes.
After a few attempts to
restart, the compressor.
The compressor does not
stop and the safety valve is
tripped.
Any other type of operation must be carried out by authorized Service Centers, requesting
original parts. Tampering with the machine may impair its safety and in any case make the
warranty null and void.
Switch off the compressor and make sure that it
is secured in such a way that it cannot be started
up again by any unauthorized person.
Warning!
Store the compressor only in a dry location which
is not accessible to unauthorized persons.
Always store upright, never tilted!

7. DISPOSAL AND RECYCLING

The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local
council.
CAUSE
Check valve that, due to wear
or dirt on the seal, does not
perform its function correctly.
Excessive performance
request, check for any leaks
from the couplings and/or
pipes. Intake filter may be
clogged.
Tripping of the thermal cutout
due to overheating of the
motor.
Tripping of the thermal cutout
due to overheating of the
motor (removal of the plug
with the compressor running,
low power voltage).
Irregular functioning of the
compressor or breakage of
the pressure switch.
17
REMEDY
Unscrew the hexagonal head
of the check valve, clean the
valve seat and the special
rubber disk (replace if worn).
Reassemble and tighten
carefully.
Replace the seals of the
fitting, clean or replace the
filter.
Clean the air ducts in the
conveyor. Ventilate the work
area.
Activate the on/off switch.
Ventilate the work area.
Wait a few minutes. The
compressor will restart
independently.
Remove the plug and contact
the Service Center.
G
B

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dn 200/8/24Dn 200/10/24

Tabla de contenido