Setting The Pressure Switch; Cleaning And Maintenance - Stanley DN 200/8/6 Manual De Instrucciones

Ocultar thumbs Ver también para DN 200/8/6:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
by a 16 A fuse. Before you use the machine,
make sure that the mains voltage complies with
G
the specifications on the rating plate. Long supply
B
cables, extensions, cable reels etc. cause a drop in
voltage and can impede motor start-up. In the case
of low temperatures below +5°C, motor start-up is
jeopardized as a result of stiffness.
5.4 On/Off switch (ref. 8)
5.4.1
D 200/8/24 - D 200/10/24 (Fig. 2a)
To switch on the equipment set the On/Off switch
(ref. 8) to position I.
Move the On/Off switch (ref. 8) to position O to
switch off the equipment.
5.4.2
D 200/8/6 (Fig. 2b)
To switch on the compressor, pull out the red knob
(ref. 8) to position I.
To switch off the compressor, press the red knob
(ref. 8) in again to position O.
5.5 Adjusting the pressure
● You can adjust the pressure on the pressure
gauge (ref. 6) using the pressure regulator (ref.
7).
● The set pressure can be taken from the quicklock
coupling (ref. 5).

5.6 Setting the pressure switch

The pressure switch is set at the factory.
5.6.1
D 200/8/6 - D 200/8/24
Switch-on pressure 6 bar
Switch-off pressure 8 bar
5.6.2
D 200/10/24
Switch-on pressure 8 bar
Switch-off pressure 10 bar
FUNCTION
Cleaning of intake filter and/or
substitution of filtering element
Draining tank condensate

6. CLEANING AND MAINTENANCE

Pull the power plug before doing any cleaning
and maintenance work on the appliance.
Wait until the compressor has completely cooled
down. Risk of burns!
Always depressurize the tank before carrying
out any cleaning and maintenance work.
6.1 Cleaning
● Keep the safety devices free of dirt and dust
● We recommend that you clean the appliance
● Clean the appliance regularly with a damp cloth
● You must disconnect the hose and any spraying
6.2 Condensation water
The condensation water must be drained off each
day by opening the drain valve (ref. 11) (on the floor
of the pressure vessel).
The condensation water from the pressure
vessel will contain residual oil. Dispose of the
condensation water in an environmentally
MAINTENANCE RESUMPTIVE TABLE
AFTER THE FIRST
100 HOURS
Periodically and at the end of work
16
Warning!
Warning!
Warning!
as far as possible. Wipe the equipment with a
clean cloth or blow it with compressed air at low
pressure.
immediately after you use it.
and some soft soap. Do not use cleaning agents
or solvents; these may be aggressive to the
plastic parts in the appliance. Ensure that no
water can get into the interior of the appliance.
tools from the compressor before cleaning. Do
not clean the compressor with water, solvents or
the like.
Warning!
EVERY 100 HOURS

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dn 200/8/24Dn 200/10/24

Tabla de contenido