Specifications - Amprobe AC68C Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Data Hold
Proceed as for voltage or current measurement (AC or DC).
While taking a measurement, press the HOLD button. "HOLD" is
shown on the display and the current meter reading is
maintained, even after disconnecting the test leads from the
circuit or removing the conductor from the clamp. Press HOLD
again to deactivate before taking a new measurement.

Specifications

General Specifications
Display: 3-3/4 Digit LCD, max. reading of 3999. Function and
unit indication.
Overrange indication: "OL" indicated.
Polarity indication: automatic; positive implied; negative
indicated.
Zero adjustment: automatic for all functions and ranges except
DC current (Zero adjustment button).
Ranging: manual function and range selection with rotary
selector switch. Autoranging for frequency measurement.
Special functions: Data Hold, Peak Hold
Operating principle: dual slope integration
Sampling rate: 2 /sec, nominal.
Maximum voltage between any terminal and earth ground: 600 V
Low Battery Indication:
operating voltage.
Auto Power Off: Approx. 30 minutes after no function change.
Environmental Conditions
Operating temperature: 0 °C to +40 °C, <80 % R.H., non-
condensing
Storage temperature: -10 °C to +60 °C, <70 % R.H., battery
removed.
Power source: Single 9 V battery (NEDA 1604,1EC 6F22)
Battery life: Alkaline 200 hours.
Maximum jaw opening: 40 mm (1.57 inches)
Pollution degree: Level II
Altitude: < 2000 meters
Size (WxLxH): 76x228x39 mm (3"x9"x1.5")
Weight: 465 gr (incl. battery)
Accessories: Test leads, battery, manual and carrying case.
when battery voltage drops below
BT
6

Publicidad

Tabla de contenido
loading

Tabla de contenido