Troubleshooting - Dometic MAGICWATCH MWE 6004 Instrucciones De Montaje

Sistema de ayuda para aparcar
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
MWE6004
13

Troubleshooting

The device shows no function.
The cables to the reversing light are not connected or are not properly connected.
The plugs for the sensors are not connected or are not correctly plugged into the
control electronics.
➤ Check the plugs and make sure they lock into place.
Flashing segments on display
Faulty sensors are indicated on the display by flashing segments that are immediately
in front of the affected sensor. The system continues to operate with the remaining
sensors.
A
NOTICE!
The system does not work correctly if one or more sensors are defective.
Replace the faulty sensor as soon as possible.
No acoustic signals
The speaker is switched off.
➤ Check whether the loudspeaker is switched on.
➤ Check whether the loudspeaker is connected correctly.
➤ Set parameter 01 to a value of 1 or 2 (see chapter "Setting the system" on page 11).
Device indicates obstacles incorrectly
False alarms may have the following causes:
Dirt or frost on the sensors.
➤ Clean the sensors.
The sensors were incorrectly installed.
➤ Adjust the position of the sensors (fig. 3).
➤ If necessary, use parameters 17 to set the sensitivity of the sensors (see chapter
"Setting the system" on page 11).
EN
Troubleshooting
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

9101500081

Tabla de contenido