17. TROUBLESHOOTING GUIDE
Malfunction
The alarm does not respond to the
transmitter.
The system is not triggered by
moving/lifting
18. TECHNICAL DATA
Power supply (control unit)
Current consumption rate
Back-up battery
Operating temperature
Siren sound power
Size of the control unit
Size of the transmitter
Transmitter battery
Transmitter battery life
Recommended inspections / operations
- Make sure the system has not entered the sleep condition (see paragraph 14)
- Operate the transmitter closer to the unit (the area might be affected by noises interfering with the radio
signal)
- Replace the transmitter battery
- Realign the transmitters (see paragraph 16.1)
- If none of these operations is successful, contact your dealer (in the meantime, if the system is armed,
disarm it with the PIN code (see paragraph 15)
- Has the inhibition time elapsed?
- Is the movement detector activated (not deselected)?
- If necessary, please adjust the movement detector (see paragraph 11).
- If none of these operations is successful, contact your dealer
Nom. 12 V Max 17 V Min. 9 V
< 1 mA OFF; 1 mA ON (including the LED)
Rechargeable 7,2V 170 mAh NiMH battery
-20 °C / +85 °C
114 dB @ 1 m
90 x 67 x 30 mm
50 x 37 x 12,5
3 V CR2032
Min.12 months (with Main-libre function on)
rev04
Operating instructions