Use inverter

10
Use inverter
10.1
Switching on inverter
➤ Put the main switch (fig. 6 1, page 4 to fig. 8 1, page 5) of the inveter in switch
position'ON'.
Set the On/Off switch to "OFF" to switch off.
➤ The inverter performs a self-test.
During the self-test, the built-in speaker emits tones and the LEDs flash.
✓ After the successful self test the LEDs 'Input level' light.(fig. 6 2, page 4 to
fig. 8 2, page 5) and 'Load Status' (fig. 6 3, page 4 to fig. 8 3, page 5)
green.
Note the following instructions in operation (see also chapter "Troubleshooting" on
page 30
The inverter switches off if:
• the battery voltage drops below 10.5 V (12 Vg connection) or 21 V
(24 Vg connection),
• the battery voltage rises over 16 V (12 Vg connection) or 32 V
(24 Vg connection),
• the inverter overheats.
➤ Switch the inverter off with the main switch in this case (fig. 6 1, page 4 to
fig. 8 1, page 5).
➤ Check that the inverter is sufficiently ventilated and that the ventilation grilles are
unimpeded.
➤ Wait about 5 – 10 minutes and switch the inverter on again without loads.
When operating the inverter at high load for lengthy periods, it is advisable to start
the engine in order to recharge the vehicle battery.