Descargar Imprimir esta página

Test C; Does Not Cool Properly In Gas Mode; Test B; Does Not Cool Properly In Ac Mode - Norcold N3104 Serie Manual De Servicio

Ocultar thumbs Ver también para N3104 Serie:

Publicidad

Troubleshooting Tests, cont'd.
Be sure you have followed the "Diag-
NOTICE
nostic Pre-Checks" before continuing.
Once the problem is corrected, you
MUST power the refrigerator off and
on to clear the fault code display.
Is the input at the power control board
120VAC ( 108V < 132V ) and Neutral (GND)?
Yes
Is the input at the heater conne on 120V?
Yes
Is AC heater resistance in range?
N3104: 66 + 4 Ohm
N3141 / N3150: 48 + 4 Ohm
Yes
Is AC heater is properly installed?
Be sure you have followed the "Diag-
NOTICE
nostic Pre-Checks" before continuing.
Once the problem is corrected, you
MUST power the refrigerator off and
on to clear the fault code display.
START
Put the unit in Manual mode.
Is the tank filled with LP gas?
Yes
Is orifice and burner clean?
Is flame dense and blue? Gas pressure
Yes
should be between 11.0 – 12.0 WC?
Yes
Does gas pressure measure 11" WC?
Yes
Is thermistor properly fitted on the 5
from right on inside of cooling cabinet?
Yes
Is spiral baffle in flue tube?
Yes
Check if burner is aligned properly in front
of flue tube.
START
Put the unit in Manual AC.
No
Is produ on date of unit prior to
Jan. 4, 2013?
No
No
No
Fill tank with LP gas.
No
Clean or replace burner and
orifice.
No
Adjust WC pressure to 11".
No
th
fin
Install thermistor in correct
location.
No
Install spiral baffle.
No
Align burner.
17
Correct AC input.
Replace power control board
No
assembly.
Replace power control board
assembly and display board.
Yes
Replace AC heater.
Install AC heater properly.

Test C

Does not cool
properly in
gas mode

Test B

Does
not cool
properly in
AC mode
N3104, N3141, N3150 Models

Publicidad

Capítulos

loading

Este manual también es adecuado para:

N3141 serieN3150 serie