Descargar Imprimir esta página

Annual Maintenance; Troubleshooting; Diagnostic Pre-Checks; Control Panel Error Codes - Norcold N3104 Serie Manual De Servicio

Ocultar thumbs Ver también para N3104 Serie:

Publicidad

ANNUAL MAINTENANCE

Annual
Maintenance
Examine the gas supply lines
for leaks
Verify that the propane gas
pressure is 11 inches of water
column
Verify that the combustion seal is
complete and intact
Verify that the burner and the
burner orifice are clean
Verify that the electrode spark
gap is 1/8 - 3/16 inch
Verfiy that the voltage is within
:
specified range
AC 108 - 132 volts
DC 10.5 - 15.4 volts
Look at the color of gas flame.
Verify that the area at the rear
of the refrigerator is free of any
combustible materials, gasoline,
and other flammable vapors and
liquids.
:
Fig. 5
Annual Maintenance Tasks

TROUBLESHOOTING

Diagnostic Pre-checks

Before performing detailed diagnostics inspect for the
:
following
1.
Make sure power switch / thermostat is not in the OFF
position.
2.
Make sure door is closed and sealing correctly.
3.
Make sure that refrigerator is correctly installed and that
the vents are not blocked.
4.
Make sure vehicle fuse or circuit breaker is intact.
5.
Make sure ambient temperature is not unusually high
(more than 110° F. / 43° C.).
6.
Make sure air circulation inside the refrigerator is not
decreased by foods or by shelves covered with plastic,
paper, etc.
7.
Make sure cooling fan is connected at the rear of the
refrigerator.
8.
Make sure freezer is defrosted.
If refrigerator does not operate after completing pre-
checks listed above, follow the procedures outlined in
the "Control Panel Error Codes" section.
If no error codes are found refer to "Troubleshooting
Symptom Chart" section.
N3104, N3141, N3150 Models
Take Action
Replace or repair if needed - refer to "Test for
Gas Leaks" procedures
Adjust if needed
Replace or repair
Clean if needed - refer to "Clean / Replace
Burner and Orifice" procedures
Adjust if needed
Correct if needed
If the flame is yellow, flickering or changing
shape, repair - refer to "Clean / Replace
Burner and Orifice" procedures.
WARNING
!
ATTENTION
DANGER of fire or explosion! Immedi-
ately take corrective action by removing
ALL combustible material that is near rear of
refrigerator!

Control Panel Error Codes

#
Problem
Lights
1
Unit senses flame
when gas mode is not
selected
2
Burner control mod-
ule senses incorrect
feedback
3
Gas lockout; flame
fails to ignite after 30
seconds
4
DC heater Off -
should be On
5
DC heater On -
should be Off
DC voltage out of
6
range
(10.0 < 15.0)
8
:
Fig. 8
Possible Cause
Take Action
■ Bad gas valve
Run Error
Code 1 Test
■ Bad power control board
and/or LCD display
■ Bad burner
Run Error
Code 2 Test
■ Bad power control board
and/or LCD display
■ Gas obstruction, gas
Run Error
empty
Code 3 Test
■ Bad electrode
■ Bad orifice or burner
■ Bad power control board
and/or LCD display
■ Bad fuse
Run Error
Code 4 Test
■ Bad DC heater
■ Bad power control board
and/or LCD display
■ Bad power control board
Run Error
and/or LCD display
Code 5 Test
■ Bad DC input source
Run Error
Code 6 Test
■ Bad (coach) solar panel
regulator or solar panel
■ Bad power control board
and/or LCD display
■ Loose connection on
power board wires
Control Panel Error Codes

Publicidad

Capítulos

loading

Este manual también es adecuado para:

N3141 serieN3150 serie