Operating Instructions SATAjet 3000 B RP/HVLP (DIGITAL)
US
US
6.4.2 Additional Information on the Electronic
Pressure Gauge
The electronic pressure gauge has passed a design examination. It has
been developed, constructed and manufactured in accordance with the
EU directive 94/9 EU. It has been classified according to II 2 G Ex ia IIC
T4 FM Global IS CL I, ZN 1, AEx ia IIC T4 IS CL I, DIV 1, GP A, B, C&D,
T4 and may be used and stored in the explosive zones 1 and 2 up to
60°C (140 F) ambient temperature. Inspection authority: KEMA 05 ATEX
1090 X.
The following applications and operations lead to the loss of
the explosion protection and are, therefore, prohibited:
• Battery replacement in explosive areas!
• Removal of the front cover of the pressure display!
• Installation of a battery other than the CR 1632 Renata!
When exchanging the battery, it is recommended to also replace the
sealing of the battery compartment!
7.
Use
• Use only solvent-resistant, antistatic, undamaged and technically flaw-
less compressed air hoses with a permanent pressure resistance of
minimum 10 bar / 145 psi, e.g. Art. No. 53090!
The following requirements must be fulfilled:
• Use of a compressed air connection G 1/4 a or of a fitting SATA con-
nection nipple.
• Ensure minimum compressed air volume (air consumption) and pres-
sure (recommended spray gun inlet pressure) according to chapter 2.
• Use clean compressed air, e.g. by installing the SATA filter 484, Art.
No. 92320
492
492
Warning! Risk of explosion!
Warning! Risk of explosion!
Information!