Disposal - SATA SATAjet 3000 B Instrucciones De Servicio

Ocultar thumbs Ver también para SATAjet 3000 B:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 142
Operating Instructions SATAjet 3000 B RP/HVLP (DIGITAL)
EN
EN
Malfunction
Spray gun does not
shut-off air
Corrosion on air cap
thread, inside material
passages (cup con-
nection) or on spray
gun body
Black digital display
Material leaks from
behind the paint nee-
dle sealing
Spray gun leaks from
the fluid tip ("fluid tip
aperture")

11. Disposal

Recycle the completely empty spray gun. To protect the environment, bat-
teries and residual paint have to be disposed in an appropriate way and
separately from the spray gun. Please observe local legislation!
128
128
Cause
Clogged air piston seat
or worn air piston
Cleaning solution
(water-based) remains
inside/on the spray
gun for too long
Unsuitable cleaning
solutions
Spray gun has been
for too long in cleaning
solution
Wrong positionining of
the spray gun inside
the gun washing ma-
chine
Defective or missing
paint needle sealing
Clogged or damaged
paint needle
Contamination be-
tween paint needle tip
and fluid tip
Damaged nozzle set
Corrective Action
Clean air piston seat
and/or replace air pis-
ton, air piston packing,
chapter 9.4
Cleaning, observe
chapter 8, get a re-
placement spray gun
body
Cleaning, observe
chapter 8, get a re-
placement digital unit
Replace / insert paint
needle sealing, chap-
ter 9.3
Replace nozzle set,
chapter 9.1; replace
paint needle sealing, if
necessary, chapter 9.3
Clean fluid tip and
paint needle, observe
chapter 8
Replace nozzle set,
chapter 9

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido