Power Saving mode or Master/Slave mode select
Mode
Power Saving Mode ON
Master/Slave mode ON
(in a system with multiple units)
Power Saving setting
The Power Saving mode saves energy from the battery in no load operation. The inverter scans the
output and compares the detected load to the set threshold value. When a load is detected which is
lower than the Power Saving threshold value, the inverter switches into Power Saving Mode. When
a load is detected which is approximately 2~3 times the threshold value, the inverter is switched
back on. Power Saving is not available when the inverter is in Master/Slave mode (DIP switch 7 =
1).
The Power Saving threshold value is set with DIP switch 4, 5 and 6. Make sure that Power Saving
Mode is selected (DIP switch 7 = 0).
Power Saving setting
Model
Threshold
value
2500/3500
Power saving
disabled
2500
50 W
3500
70 W
2500
75 W
3500
105 W
2500
100 W
3500
140 W
2500
125 W
3500
175 W
2500
150 W
3500
210 W
2500
175 W
3500
245 W
2500
200 W
3500
280 W
Master/Slave mode setting
Master/Slave mode is only applicable when the unit is used in a system with multiple units for
parallel configuration or 3 phase configuration. Make sure that Master/Slave mode is selected (DIP
switch 7 = 1).
DIP switch 7
0
1
DIP switch 4
DIP switch 5
0
1
0
1
0
1
0
1
DIP switch 6
0
0
0
0
1
0
1
0
0
1
0
1
1
1
1
1
19
ENGLISH
DIP switch 7
0
0
0
0
0
0
0
0

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ac master 24/2500Ac master 12/3500