_MSP702_MSP2524.book Seite 52 Dienstag, 22. September 2009 4:55 16
Cleaning and caring for the inverter
12
Cleaning and caring for the inverter
Caution
a
Do not use sharp or hard objects or cleaning agents for cleaning as
these may damage the device.
➤ Occasionally clean the device with a damp cloth.
13
Troubleshooting
Note
I
If you have detailed questions on the specifications of the
inverter please contact the manufacturer.
Warning!
e
Do not open the device. You risk sustaining an electric shock by do-
ing this.
No output voltage
The "Power Status" LED (fig. 2 2, page 4) displays the fault in red:
LED display
Cause
Quick flashing
Input voltage too high
Slow flashing
Input voltage too low
Occasional flash-
Overheating
ing
Constantly lit
Short circuit or
reversed polarity
Excessive load
52
Remedy
The inverter is only intended for the voltage indi-
cated.
The battery needs charging.
Check the cables and connections.
Switch off the inverter and the appliance.
Wait 5 to 10 minutes and switch the inverter on
again without any appliances.
Reduce the load and make sure the inverter has
better ventilation. Then switch the appliance back
on.
Switch off the inverter and remove the appliance.
Then switch the inverter back on without the appli-
ance. If no excessive load is now shown, then
there is a short circuit in the appliance or the total
load was higher than the power specified on the
data sheet.
Check the cables and connections.
SinePower