Correct Usage / Operational Conditions
Use the tubular motors only to open and close roller blinds and
awnings.
IMPORTANT
The motor cable must be run inside the empty tube, in compliance
with the local electrical codes, to the junction box.
Use only original components and accessories from the manu-
facturer.
Important installation instructions
IMPORTANT
Please compare the voltage/frequency specifications on the type plate
with those of your local power supply network before installation.
Disassemble or deactivate all cables and equipment that will not
be needed for operation before installing the tubular motor.
The moving parts of drives that are operated at less than 2.5 m
height from the floor must be protected.
If the tubular motor is controlled with a preset OFF switch this
switch must be fitted within view of the tubular motor, at a
minimum height of 1.5 m and away from moving parts.
It is vital that the winding shaft is fitted horizontally!
It is vital that the roller shutter is wound up evenly, as this could
otherwise cause damage to the motor and shutter.
The roller shutter box cover must be easily accessible and
removable.
Do not disassemble the mecanical stoppers on the last shutter slat.
Operational Conditions
For the electrical connection, a 230 V/50 Hz power drop must be
continuously available at the installation site, with a disconnect
device (cut-out) provided by the customer.
For automatically operated awnings:
Awnings must be fitted in such a way that there is a minimum
distance of 0.4 m between the awning and objects in its immediate
proximity when it is fully extended.
The lowest point of any awning system must not be less than 1.8 m
high.
GB