If the charging voltage regulator cuts the connection to the supply battery due
to low voltage, it switches off the roof air conditioner at the same time. The
inverter remains active and has voltage in its socket.
As soon as the voltage in supply battery has reached the switch-on point in the
charging current distributor, the roof air conditioner switches on again.
If the voltage in the supply battery drops further and goes below the 10.5 V
switch-off point for the inverter, the inverter switches off (chapter "Driving mode:
power supply from the 12 V battery with motor switched off" on page 22).
• B1600
If the charging voltage regulator cuts the connection to the supply battery due
to low voltage, it switches off the inverter at the same time using the RC2 remote
control. There is no voltage in the socket for the inverter.
As soon as the voltage in the supply battery reaches the switch-on point in the
charging current distributor, it restores the connection between the starter and
supply battery and switches the inverter on again using the RC2 remote control.
There is voltage in the socket again for the inverter.
The air conditioning starts again automatically.
If the voltage in the supply battery drops further and goes below the 10.5 V
switch-off point for the inverter, the inverter switches off (chapter "Driving mode:
power supply from the 12 V battery with motor switched off" on page 22).
8.2

Switching off the system

➤ First of all, switch off the air conditioning.
➤ Switch off the inverter using the remote control.
9

Maintaining and cleaning the DC kit

I
NOTE
Observe the maintenance and cleaning instructions in the operating
manuals of the individual components.
➤ Check the power supply lines for abrasion or defects regularly.
➤ Have the system checked regularly by a specialist.
➤ If you find any faulty fuses, have the system checked by a specialist.