Clean the remote control with a slightly damp cloth from time to time. We
recommend using a cleaning cloth for glasses to clean the display.
10

Troubleshooting

Possible
Cause
malfunction
Device con-
Icing sensor has tripped.
stantly switches
itself off.
No cooling
The device is not set to cooling.
capacity
The ambient temperature is above
43 °C.
The temperature set is above the
room temperature.
The temperature sensor is defective.
The vaporiser fan is damaged.
The condensor fan is damaged.
No heating
The ambient temperature is above
capacity
30 °C.
The device is not set to heating.
The temperature sensor is defective.
Low air output
The air intake section is clogged up.
The vaporiser fan is damaged.
Water enters the
The condensation water drainage
vehicle
openings are clogged up.
The seals are damaged.
Air conditioner will
There is no voltage.
not go on
The voltage is too low
(under 200 V).
The voltage converter is defective.
The temperature sensor is damaged.
The electrical fuse of the power sup-
ply is too low.
Air conditioner is
The temperature sensor is defective.
unable to be
switched off
Troubleshooting
Remedial measure
Outer temperature is too low or all
air nozzles are closed.
Set the device to cooling.
The roof air conditioner is only
designed for ambient temperatures
of up to 43 °C.
Select a lower temperature.
Consult an authorised special-
ist workshop.
Only use the heating function
of the roof air conditioner at
temperatures below 25 °C.
Set the device to heating.
Consult an authorised special-
ist workshop.
Ensure unhindered air supply
at the air intake units.
Consult an authorised special-
ist workshop.
Clean the drainage openings
for condensation water.
Consult an authorised special-
ist workshop.
Check the power supply.
Consult an authorised special-
ist workshop.
Check the electrical fuse of the
power supply.
Consult an authorised special-
ist workshop.