Troubleshooting

8
Troubleshooting
Problem
Cause
No cooling
The under-bench air conditioner is
capacity
not set to cooling.
The ambient temperature is above
43 °C.
The temperature set is higher that the
room temperature.
The ambient temperature is below
16 °C.
The thermal protection is defective.
The compressor is damaged.
The refrigerating agent filling is
insufficient.
The heat exchange coils are polluted.
The external blower is defective.
Low air output
The air filter is obstructed.
The heat exchange coils are polluted. ➤ Contact an authorised work-
The internal blower is defective.
Water enters the
The condensation water drainage
vehicle
openings are clogged up.
The seals are damaged.
Under-bench air
No supply voltage (230 Vw) con-
conditioner does
nected.
not switch on.
The voltage is too low (under
200 Vw).
The voltage converter is defective.
The defective thermal protection is
defective.
The condenser fan is damaged.
The compressor is damaged.
The electrical fuse of the power
supply is too low.
24
Dometic FreshWell 2000
Remedy
➤ Set the under-bench air condi-
tioner to cooling.
The under-bench air conditioner is
only designed for ambient temper-
atures of up to 43 °C.
➤ Select a lower temperature.
The under-bench air conditioner is
only designed for ambient temper-
atures above 16 °C.
➤ Contact an authorised work-
shop.
➤ Clean the air filter.
shop.
➤ Clean the drainage openings
for condensation water.
➤ Contact an authorised work-
shop.
➤ Check the power supply.
➤ Contact an authorised work-
shop.
➤ Check the electrical fuse of the
power supply.