Installing the stove

The floor on which the stove is installed must be even
and horizontal. The stove may only be installed on an
adequate load-bearing floor. The stove can be stood on
a metal floor sheet or glass sheet to protect the floor-
ing.
If the flooring or carpet is inflammable, a stable, heat
proof spark protection plate must be used. This must
extend 50 cm to the front and 30 cm to each side be-
yond the edge of the combustion chamber opening.
Under the stove no spark protection plate is required.

Assembly sequence

Since by the installation of the side cladding and the
OEC (manuals are included with the respective pack-
aging units) and by the connection change of the con-
nection support, the cover hood is removed, the reas-
sembly of the cover hood should only occur if all add-
on parts are attached.
● Remove the top cover.
● Unscrew the paneling for water connections of the
back panel (Fig. 1).
● Unscrew the back panel (Fig. 2).
● Slide the temperature sensor of the "Temperature
Difference Controller" into the right-hand sen-
sor pocket and secure it using the threaded screw
(Fig. 3).
● The connection of the flue Ø 150 mm may optional-
ly occur from above or from the back. The device is
delivered for connection installed from above.
If there should be a rear connection, it must be in-
stalled in the following steps:
- Break out the cover in the back panel.
- Replace the connector sleeve and the sealing cov-
er.
● Screw the pack panel.
● If required, assemble OEC.
● Install side cladding.
● Place the top cover back.
● Flue connection from the back: Close off the hole in
the top cover with the en-closed insertable cap.
● Decide where the stove is to be installed. There
must be no objects made of combustible materials
within a distance of 80 cm of the stove's radiation
area, measured from the combustion chamber's in-
spection glass, nor may any be placed within this
area subsequently.
Minimum distance from combustible or load-
bearing walls: lateral 10 cm and rear 10 cm
16
Fig. 1 Paneling for water connections
Fig. 2 Unscrew the back panel
Fig. 3
Sensor pocket
for TAS
Sensor pocket for
temperature sensor
„Temperature Difference
Controller"