be withdrawn from service and sent
back to the manufacturer or a quali-
fi ed repair centre for checking, or des-
truction. Following examination, the
centre will either deliver or refuse writ-
ten authorisation to re-use the PPE. It
is strictly forbidden to modify or repair
a PPE yourself. Only the manufacturer
or a repair centre is qualifi ed to carry
out these repairs.
Check the serviceable condition of the
harness : ( cf. 7 ) :
No incipient breaks in the
webbing,
No deformation of the D-links,
Correct operation of the buckle
systems,
Integrity of the seams,
Good condition of the metal
components.
SPACE CLEARANCE
If there is a risk of falling, or if ancho-
rage cannot be provided below the
attaching points of the harness, it is
essential to use a lanyard fi tted with
an energy absorber Before using an
energy absorber incorporated into a
lanyard, check for a minimum space
clearance below the user's feet as ne-
cessary, to prevent any collision with
the structure or the ground. With a
weight of 100 kg and a fall factor of
two ( worst case scenario ), the air
clearance D is the stopping distance
H ( 2L+1.75m ) plus an additional dis-
tance of 1 m. ( cf. 8 ). Important: if the
harness is equipped with an extension
strap, take this into account when cal-
culating the clearance distance.
PERIODIC EXAMINATION
These instructions must be kept with
the product. Fill in the identifi cation
sheet and enter the markings informa-
tion. This periodic examination, which
verifi es the eff ectiveness and strength
of the equipment is indispensable
in guaranteeing the user's safety. A
qualifi ed person must examine this
equipment at least once each year,
in strict compliance with the instruc-
tions of the manufacturer and the
examination must be recorded on
the attached sheet. The frequency of
the examination must be increased in
accordance with regulations in case
of heavy usage or in diffi cult environ-
mental conditions. The legibility of the
10
product markings must be checked.
LIFESPAN
The maximal life of PPE that is predo-
minantly textile is evaluated as being
10 years after the date of manufac-
ture. However, the following factors
may reduce the performance of the
product and its lifespan : incorrect
storage, improper use, fall arrest,
deformation, contact with chemical
products (alkali and acid), exposure to
sources of heat > 60°C ( cf. 9 ).
ANCHORAGE POINT
If possible, to be used with achorage
devices (conformed to the EN 795
standard) or structural anchor. that is
to say elements fi xed to last, to a struc-
ture (wall, post...).
Check that the anchorage point :
Offers minimum resistance of
12 kN,
Is situated above the operator, (
cf. 10 ).
Is vertically in line with the wor-
king surface: (maximum angle
± 30°),
Is totally suited to the equipment
attaching device
Has no sharp edges
MAINTENANCE AND STORAGE
Good maintenance and storage of
your PPE will prolong the working-life
of your product, while also ensuring
your safety ( cf. 9 ). Be sure to comply
with these recommendations:
The harness should be cleaned
with water and a mild soap. Never
use acid, solvents or any solvent-
based product,
Leave to dry in a well-ventilated
area, away from sources of heat.
Store the harness away from
humidity and ultraviolet light,
Avoid any atmosphere that is
corrosive or excessively hot or
refrigerated.
CARABINER
Connector is compliant with standard
EN 362
When the carabiner is used for
attachment to an anchorage
point, check for compliance with