Technical Specifications - Stihl RME 235 Manual De Instrucciones

Ocultar thumbs Ver también para RME 235:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
TÜV Rheinland LGA Products GmbH
Tillystraße 2
D-90431 Nürnberg
Compilation and storage of technical
documentation:
Sven Zimmermann
STIHL Tirol GmbH
The year of manufacture and machine
number appear on the rating plate of the
machine.
Measured sound power level:
92,1 dB(A)
Guaranteed sound power level:
93 dB(A)
Langkampfen,
2020-01-02 (YYYY-MM-DD)
STIHL Tirol GmbH
p.p.
Matthias Fleischer, Research and
Development Division Manager
p.p.
Sven Zimmermann, Quality Division
Manager
0478 121 9804 A - EN

17. Technical specifications

Type
RME 235.0
Serial number
6311
Motor, design
Electric motor
Motor type
Universal AC
motor
Voltage
230 V~
Power input
1200 W
Frequency
50 Hz
Fuse
5 A
Protection class
II
Type of protection
IPX 4
Cutting device
Cutter bars
Cutting width
33 cm
Speed of cutting
device
3200 rpm
In accordance with Directive 2000/14/EC:
Guaranteed sound
power level L
93 dB(A)
WAd
In accordance with Directive 2006/42/EC:
Sound pressure level
at workplace L
80 dB(A)
pA
Uncertainty K
2 dB(A)
pA
Cutter bar drive
Permanent
Blade fastening
screw tightening
torque
15 - 20 Nm
Wheel diameter
(front)
140 mm
Wheel diameter
(rear)
170 mm
Grass catcher box
capacity
30 l
Cutting height
25 - 65 mm
Specified vibration characteristic in
accordance with EN 12096:
Type
RME 235.0
Measured value a
1,40 m/sec
hw
Uncertainty K
0,70 m/sec
hw
Measurement in accordance with
EN 20643
Length
127 cm
Width
37 cm
Height
108 cm
Weight
13 kg
14 kg (GB)
17.1 REACH
REACH is an EC Directive for the
registration, evaluation, authorisation and
restriction of chemicals.
Information on compliance with the
REACH Directive (EC) No. 1907/2006 is
available from www.stihl.com/reach.
18. Troubleshooting
If necessary, contact a specialist
dealer; STIHL recommends STIHL
specialist dealers.
Fault:
Motor does not start
Possible cause:
– No mains voltage
– Connection cable, plug, plug connector
or switch defective
– Start button not pressed
– Motor is overloaded because the grass
is too tall or too wet
– Motor overload protection activated
– Mower housing is blocked
2
2
21

Publicidad

Tabla de contenido
loading

Tabla de contenido