1.2.
DURING USE
Remove the clamp jaw from the conductor or circuit under test before changing the
range.
When the tester is connected to the measuring circuits, do not touch any unused
terminal.
Do not measure resistance in the presence of external voltages. Even if the circuit is
protected, excessive voltage could cause the instrument to malfunction.
When measuring current with the clamp jaws, first remove the test leads from the
instrument's input jacks.
When measuring current, any other source near the clamp jaw could affect its
accuracy.
When measuring current, always put the conductor to be tested in the middle of the
clamp jaw to obtain the most accurate reading as referred into § 4.1.2.
While measuring, if the value remains unchanged check if the HOLD function is
enabled
1.3.
AFTER USE
After taking measurements turn off the clamp
If the instrument is not be used for a long period, remove the battery
1.4.
DEFINITION OF MEASURING (OVERVOLTAGE) CATEGORY
The norm IEC/EN61010-1: Safety requirements for electrical equipment for measurement,
control and laboratory use, Part 1: General requirements, defines what a measuring
category, usually called overvoltage category, is.
Circuits are divided into the following measurement categories:
Measurement category IV is for measurements performed at the source of the low-
voltage installation
Examples are electricity meters and measurements on primary overcurrent protection
devices and ripple control units
Measurement category III is for measurements performed in the building installation
Examples are measurements on distribution boards, circuit breakers, wiring, including
cables, bus-bars, junction boxes, switches, socket-outlets in the fixed installation, and
equipment for industrial use and some other equipment, for example, stationary motors
with permanent connection to fixed installation
Measurement category II is for measurements performed on circuits directly
connected to the low voltage installation
Examples are measurements on household appliances, portable tools and similar
equipment
Measurement category I is for measurements performed on circuits not directly
connected to MAINS
Examples are measurements on circuits not derived from MAINS, and specially
protected (internal) MAINS-derived circuits. In the latter case, transient stresses are
variable; for that reason, the norm requires that the transient withstand capability of the
equipment is made known to the user.