TEChNICAL DATA

This wet and dry cleaner is double insulated so does not require earthing (grounding). Before carrying out any repairs, always
follow any instructions concerning double insulated appliances. Only use your Aquavac as intended and in accordance with
these Operating Instructions.
Supply voltage
Max. power
Tank volume
hose system Ø
Filter – dry:
Filter – wet
2200W max
= maximum load of the integrated appliance outlet
oVErVIEW oF ThE APPLIANCE CoMPoNENTS (B1)
Unpack your Aquavac carefully and use the check list to check the contents.
1. Handle
2. Upper section
3. Filter basket
4. Hose set
5. Nozzle
6. EXCELL 24S Synchro: Connectable tube (×2)
EXCELL 30S Synchro: Ratchet telescopic
7. Joint and crack nozzle
8. Upholstery nozzle
9. Foam plastic filter
10. Dust bag
11. Plaited filter
12. Float switch
13. ON/OFF switch
14. EXCELL 24S Synchro: Rollers (X4)
EXCELL 30S Synchro: Front rollers (X2)
15. Tank
16. Clamps (x2)
17. Connection for the vacuum hose
18. Handle section with air-leak slider
19. Drain plug
20. Only EXCELL 30S Synchro: Rear wheels (X2)
21. Squeegee nozzle
22. Power tool adapter
30
Excell 24S Synchro
Excell 34S Synchro
230 V/50 Hz
1000 W
1000 W
20L inox tank
30L inox tank
35 mm
Paper bag/plaited filter (optional foam with dry filter)
plastic foam

PACKAGING CoNTENT

Carefully unpack the contents of the box. Hold the two clamps (16) (B1), which hold the upper section (2) (B1) in its position
and fold them upwards (B2).
Loosen the clamps, remove the upper section (B3), and remove the contents from the tank. Please check the parts using the
overview (B1) to make sure they are complete and that there has been no damage in transport. If any parts are missing or
damaged, then please contact your dealer immediately.

ASSEMBLy

Make sure that the connector is not plugged in. Hold the two clamps, which hold the upper section in its position and fold
them upwards (B2).
Loosen the clamps and lift the upper section up and out (B3).
Turn the tank over so that the upper section is on the bottom. Put the two rear wheels (20) in the side guides on the bottom of
the tank (B4).
EXCELL 24S Synchro: Put the four rollers (14) in the guides on the bottom of the tank (B5).
EXCELL 30 Synchro: Put the two rear wheels (20) in the side guides on the bottom of the tank (B4). Put the two front rollers (14)
in the guides on the bottom of the tank (B5).
Check that the rollers have been pushed completely into the guides. Insert the foam plastic filter (9) that has been supplied for
wet vacuuming. (see the section called "Wet Vacuuming") Insert the dust bag (10) that has been supplied for dry vacuuming.
(see the section called "Dry Vacuuming") Replace the upper section on the tank (B6).
Hook the clamps into the upper section and let them snap into place by pressing the clamps downwards (B7).
Place the large end of the hose (4) on the front air intake stub (17) on the tank (B8).
Select a nozzle (5, 7, 8, 22, 23) (B1) or the ratchet telescopic tube (6) (B1) and slide it over the suction tube (4) (B1), (B9).
Wet/Dry combination nozzle (5): for vacuuming carpets, smooth surfaces and liquids.
Snap the lever forwards for carpets and deep pile fitted carpeting.
Snap the lever backwards for hard floors and hardwearing short pile fitted carpeting and for vacuuming liquids covering a
large area.
handle section with air-leak slider
Open the air leak slider on the handle to regulate the airflow or to remove articles that are stuck to the nozzle (B17).
After using and cleaning the appliance, store the accessories by attaching them to the corresponding holders on the vacuum
cleaner (B18).

Dry VACUUM CLEANING

ATTENTIoN! It is absolutely necessary for you to read, understand, and observe the section entitled
!
"Safety Instructions and Warnings".
NoTE:
Never vacuum up hazardous materials. If an incorrect dust bag is used, guarantee becomes void.
Make sure that the appliance is not plugged into the power mains.
Make sure that Plaited filter (11) (B1) is installed over the filter basket (3) (B1) (B10).
Slide the dust bag (10) over the hose connection (B11) in the tank. Press it until it snaps firmly into place (B12). In the process,
make sure that the dust bag is not damaged.
Place the upper section on the tank once again and close the clamps (B5), (B6).
Place the large end of the hose on the front air intake stub (17) on the tank (B7) and screw it in by turning to the right.
Select a nozzle (5, 7, 8, 19) (B1) or the connectable tube (6) (B1) and slide it over the suction tube (4) (B1), (B8).
Make sure that the ON/OFF switch (13) (B1) on the appliance is in the "Off" position (position "0") before you plug the power
plug into the receptacle. Plug the power plug into the receptacle. Switch the motor on (ON/OFF switch in position "I").
When you have finished vacuuming, switch the motor off by putting the ON/OFF switch (13) (B1) into the "OFF" position
(position "0").
Unplug the power plug. Check the dust bag (10) (B1) regularly and change it when it is 2/3 full. The bag is designed such that
only air, and no dust, can pass through the paper.
Therefore a used dust bag may not be reused.
NoTE:
!
Don't use the dust bag for vacuuming up objects with sharp edges or wet objects.