Vacuuming with the Plaited Filter (11)
When using the plaited filter (11), no dust bag (10) and no foam plastic filter (9) is necessary. Remove them if need be.
Place the plaited filter on the filter basket 3 (B10) from the top. After extended use, it can be cleaned by banging it out or
brushing it out. Empty the container (15) in the garbage bin after vacuuming.

WET VACUUM CLEANING

ATTENTIoN! It is absolutely necessary for you to read, understand, and observe the section entitled
!
"Safety Instructions and Warnings".
NoTE:
Never vacuum up hazardous materials.
Make sure that the appliance is not plugged into the power mains. Check to make sure that the tank (15) (B1) is free of dust and
dirt. Remove the dust bag (10) (B1) or the plaited filter (11) (B1).
Only leave the foam plastic filter (9) (B9) over the filter basket. Place the upper section on the tank once again and close the
clamps (B5), (B6).
Place the large end of the hose on the front air intake stub (17) on the tank (B8) and screw it in by turning to the right. Select a
nozzle (5, 7, 8, 19) (B1) or the connectable tube (6) (B1) and slide it over the suction tube (4) (B1), (B7).
Make sure that the ON/OFF switch (13) (B1) on the appliance is in the "Off" position (position "0") before you plug the power
plug into the receptacle. Plug the power plug into the receptacle.
Switch the motor on (ON/OFF switch in position "I"). When you have finished wet vacuuming, switch the motor off by putting
the ON/OFF switch (13) (B1) into the „OFF" position (position „0").Unplug the power plug.
After use, empty and dry the tank (15) (B1).
Tips: If you want to vacuum up a large quantity of liquid from a sink or a tank, please don't put the entire suction nozzle in the
liquid; rather leave a little space so that some air can also be drawn in along with the liquid, or use the air-leak slider that is
included on the handle section (18). To do this, connect the suction tube (4) and leave the air-leak slider open.
The appliance is equipped with a float switch (12) (B1) that will stop the vacuuming when the tank is full. You will notice that
suction has stopped by the motor now running faster. In this event, switch the appliance off and unplug it.
Be aware that the full tank can be very heavy. In this event, place the appliance over a drain and carefully open the outlet screw
(18) (B1) (B19).
The contents of the tank can now drain out to a great extent. Now, remove the upper section from the tank (B3) and pour the
rest of the liquid into a suitable tank or drain. Then, you can continue vacuuming after you have replaced the upper section
(B5).
After wet vacuuming, switch off the appliance and unplug it. Empty the container and clean/dry it inside and outside before
putting it away.
Important Information!
After wet vacuuming, please proceed as described in the section entitled „Dry Vacuuming" before
you dry vacuum again.

BLoWEr FUNCTIoN

Insert the larger end of the hose in the blower outlet at the back of the motor unit.
Ensure that the On/Off switch is in the Off ("0") position before plugging in (Fig. 1).
Switch on. (Fig. 2)
The hose will now produce a powerful jet of air. This reverse airflow is useful for dislodging objects stuck in the hose. (Fig. 3)
NB:
If the blockage in the hose is not dislodged after a few seconds, switch off and extract it by hand.
32
FITTING AND CLEANING ThE CorrUGATED FILTEr
Fitting the corrugated filter
First check that you have unplugged the Aquavac (Fig. 1).
Lift off the motor unit and turn it over.
Push the corrugated filter over the float cage and carefully push it downwards (Fig. 2).
Put the retaining ring on the corrugated filter and using the grip rotate it firmly clockwise (Fig. 3).
removing and cleaning the corrugated filter
Undo and remove the filter retaining ring by turning the grip anti-clockwise (Fig. 3).
Lift off the corrugated filter. (Fig. 4)
Clean the corrugated filter by tapping it and brushing it. To avoid spreading dust this is best done out of doors.
INSTALLING & CLEANING FoAM SLEEVE FILTEr
Installing Foam Sleeve Filter
1. Verify that the power cord is disconnected from the outlet. (fig.1)
2. Remove power head and place in upside down position. Follow instructions to remove cloth filter.
3. Carefully slide foam sleeve filter down over the filter cage making sure the whole cage is covered. (fig.2 & 3)
4. Replace the power head on to the container.
Cleaning Foam Sleeve Filter
1. With the removed power head in the upside down position, carefully remove foam sleeve filter. (fig. 4)
2. Use a mild soap and water solution to wash foam sleeve filter and rinse with clean water. (fig. 5)
3. Allow filter to air dry before installing and using again.
INTEGrATED APPLIANCE oUTLET
Electric tool such as: jigsaw or circular saws up to a maximum of 2200 watts can be
connected directly to the integrated appliance outlet on the vacuum cleaner (B14).
Connect the vacuum hose Ø 35mm to the machine's suction supports. (Use the
electric tool adapter supplied. Other suitable adapters are available from your local
dealer or DIY store.)
Connect the machine to the outlet of the vacuum cleaner. Plug-in the vacuum
cleaner.
Switching on: turn on/off switch to position „II".
Switching off: turn on/off switch to position „0".
Switch on the electric tool and let it run for a short time at high speed. The vacuum cleaner will switch on automatically after a
short time and will vacuum up the dust and shavings while you work.
Delayed shut-off
After switching off the electric equipment, the vacuum cleaner will run for a while and vacuum the machine and the vacuum
hose free of dust and shavings.