Defrosting The Cooler; Replacing The Plug Fuse (12/24 V); Replacing The Light Bulb - Waeco CoolFreeze CDF16 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
Operation
6.9

Defrosting the cooler

Humidity can form frost in the interior of the cooling device or on the vapor-
iser. This reduces the cooling capacity. Defrost the device in good time to
avoid this.
A
NOTICE! Danger of damage!
Never use hard or pointed tools to remove ice or to loosen objects
which have frozen in place.
To defrost the cooler, proceed as follows:
➤ Take out the contents of the cooling device.
➤ If necessary, place them in another cooling device to keep them cool.
➤ Switch off the device.
➤ Leave the cover open.
➤ Wipe off the defrosted water.
6.10

Replacing the plug fuse (12/24 V)

➤ Pull the adapter sleeve (fig. 4 4, page 4) off of the plug.
➤ Unscrew the screw (fig. 4 5, page 4) out of the upper half of the housing
(fig. 4 1, page 4).
➤ Carefully raise the upper half of the housing from the lower (fig. 4 6,
page 4) half.
➤ Take out the contact pin (fig. 4 3, page 4).
➤ Replace the defective fuse (fig. 4 2, page 4) with a new one that has the
same rating (8A 32V).
➤ Re-assemble the plug in the reverse order.
6.11

Replacing the light bulb

➤ Press the switch pin (fig. 5 2, page 4) downwards so that the transpar-
ent part (fig. 5 1, page 4) of the lamp can be removed at the front.
➤ Replace the light bulb.
➤ Press the transparent part of the lamp back into the housing.