Replacing the plug fuse (12/24 V) (fig. 5, page 4)
6.10
Switching off the cooling device (fig. 1, page 3,
fig. 2, page 3)
➤ Empty the cooling device.
➤ Switch the cooling device off: Press the ON/OFF button (1) for three sec-
onds.
➤ Disconnect the plug.
If you do not want to use the cooling device for a longer period of time:
➤ Leave the lid slightly open. This prevents smells from building up.
6.11
Defrosting the cooling device
Humidity can form frost in the interior of the cooling device or on the vaporis-
er. This reduces the cooling capacity.
Defrost the device in good time to avoid this.
A
NOTICE! Risk of damage to the device!
Never use hard or sharp tools to remove ice or to free objects fro-
zen onto the device.
To defrost the cooling device, proceed as follows:
➤ Empty the contents.
➤ If necessary, put them in another cooling device to keep them chilled.
➤ Switch off the device.
➤ Leave the lid open.
➤ Wipe off the condensate.
7
Replacing the plug fuse (12/24 V)
(fig. 5, page 4)
➤ Pull the adapter sleeve (4) off of the plug.
➤ Unscrew the screw (5) out of the upper half of the housing (6).
➤ Carefully lift the upper half of the housing off the lower half (1).
➤ Take out the contact pin (3).
32
CoolFreeze
EN