_MPV-32.book Seite 18 Montag, 26. April 2004 1:44 13
LED
Left
(2 2, page 3)
Right
(2 4, page 3)
6.3
Switching off the cooler
➤ Press the "OFF" button (2 3, page 3) on the control panel.
If you want to switch off the device, pull out the connection cable.
6.4
Using the battery monitor
The battery monitor protects your vehicle battery against discharging
too much when the device is connected to the on-board 12 V supply.
This ensures that the vehicle has enough energy to start.
The LED's on the control panel (2 2 and 4, page 3) show the status of the
battery monitor:
Operating display
LED glows
LED's flash
18
Operating mode
Cooling
Heating
Operating mode
The switch-on voltage (12.8 V ±0.3 V) is available
and the cooler is in operation.
The switch-off voltage (11.5 V ±0.3 V) has been
reached and the battery monitor has switched off
the cooler.
MPV-32