CFX35 – CFX65DZ
6.11
Replacing the device fuse
D
DANGER! Danger of electrocution!
Disconnect the connection cable before you replace the device
fuse.
➤ Pull off the connection cable.
➤ Pry out the fuse insert (fig. 4 2, page 4) with a screwdriver.
➤ Replace the defective fuse with a new one that has the same
rating (T4AL 250V).
➤ Press the fuse insert back into the housing.
6.12
Replacing the plug fuse (12/24 V)
➤ Pull the adapter sleeve (fig. 9 4, page 5) off of the plug.
➤ Unscrew the screw (fig. 9 5, page 5) out of the upper half of
the housing (fig. 9 6, page 5).
➤ Carefully lift the upper half of the housing off from the lower
(fig. 9 1, page 5) half.
➤ Take out the contact pin (fig. 9 3, page 5).
➤ Replace the defective fuse (fig. 9 2, page 5) with a new fuse
that has the same rating (10 A).
➤ Re-assemble the plug in the reverse order.
6.13
Replacing the light PCB
➤ Pry out the transparent cover with a screwdriver (fig. 0 1,
page 5).
➤ Unscrew the PCB mounting screws (fig. 0 2, page 5).
➤ Pull out the plug from the PCB (fig. 0 3, page 5).
➤ Replace the defective light PCB with a new one.
➤ Fit new PCB using reverse of removal instructions.
➤ Press the transparent cover back into the housing.
EN
Operation
41